Document Number Service Literature
S600-001-1 Aluminum & Coppertop Compression Connector Crimp Chart
S600-100-1 600 A 15 kV Class Cleer Loadbreak Connector System Installation Instructions
S600-100-2 600 A 15 kV Class Cleer Loadbreak Insulated Protective Cap Installation Instructions
S600-100-3 600 A 15 and 25 kV Class Cleer Loadbreak Standoff Bushing Installation Instructions
S600-103-1 600 A, 15 and 25 kV Class Clēēr Grounding Elbow Installation Instructions
S600-10-2 600 A 15/25 kV Class BOL-T and Separable Splice Connector Assembly Installation Instructions (Replaces S600-10-6)
S600-15-3 600 A 15 kV and 25 kV Class BT-TAP Connector System Installation Instructions (Replaces S600-15-1, S600-10-4)
S600-50-2 600 A 35 kV Class BOL-T Connector Assembly Installation Instructions
S600-13-1 600 A PUSH-OP Connector Operation Instructions
S600-14-1 600 A U-OP Visible Break Connector System Operation Instructions
S600-14-2 600 A U-OP Visible Break Connector System Installation Instructions
S600-63-1 600 A 15/25 and 35 kV Class Deadbreak Protective Cap Installation Instructions
S600-46-2 600 A 15/25 kV Class DT625 T-Body Installation and Cable Preparation Instructions
S600-13-3 600 A 15/25 kV Class PUSH-OP Terminator Installation Instructions
S600-19-1 600 A 15,  25, and 35 kV PUSH-OP Bushing Adapter Cap Installation Instructions
S600-53-3 600 A 35 kV Class PUSH-OP Deadbreak Connector Installation Instructions
S600-52-1 600 A 35 kV Class T-OP II Connector Assembly Installation Instructions
S600-59-1 600 A 15, 25, and 35 kV Class Bushing Adapter Installation Instructions (Replaces S600-18-1)
S600-65-1 600 A 15/25 and 35 kV Class PUSH-OP Insulated Standoff Bushing Installation Instructions (Replaces S600-25-1)
S600-59-3 600 A 15 kV, 25 kV and 35 kV Class Bushing Extender Installation Instructions (Replaces S600-18-3)
S600-55-1 600 A 35 kV Class BT-TAP Connector System Installation Instructions
S600-12-3 600 A 15/25 kV Class T-OP II Connector Assembly Installation Instruction
S600-12-1 600 A T-OP II Terminator Operation Instructions
S600-46-1
(Discontinued)
Cable Training Tool Operating Instructions
S600-24-1 600 A 15, 25, 35 kV Class Insulated Standoff Bushing (5000050605)
S600-24-2 15, 25 & 35 kV Deadbreak Grounding Standoff Bushing (5000050541)
S600-22-1 15, 25 & 35 kV Deadbreak Junction (5000050607)
S600-10-3
(Discontinued)
BOL-T on TSA (5000050741)
Document Number Reference Literature
R600-01-1 15/25 kV Class 600 A Cable Adapter ICEA Cross Reference Data
B100-02034 Cooper / Elastimold Cross Reference Guide
Document Number Test Report
CP9141 The Cooper Power Systems Multi-Stress Test
CP1120 Cleer Loadbreak Separable Connector System Test Report
CP1204 600 A 25 kV Class Cleer Loadbreak Separable Connector System Certified Test Report
CP1205 600 A 28 kV Class Cleer Loadbreak Separable Connector System Certified Test Report
Document Number Service Literature
S550-10-1 200 A 15 & 25 kV Class Deadbreak Elbow Connector
S550-12-1 200 A 15/25 kV Class Deadbreak Straight Connector Installation Instructions
IS550-10-1 DE250 Deadbreak Elbow Connector Installation Instructions
IS550-10-2 DS250 Deadbreak Straight Connector Installation Instructions
IS550-11-1 DS250 Deadbreak Straight Connector Installation Instructions-Interface A
IS550-12-1 DJ250, DJ250-T1, DJ250-T2, DJ250-4 Installation Instructions
IS550-13-1 DRC250 Plug-In Receptacle Cap Installation Instructions
IS550-13-2
DPE250 Earthing Plug Installation Instructions
IS550-13-3 DPD250 Dead-end Plug Installation Instructions
IS550-20-1 DE400 Deadbreak Elbow Connector Installation Instructions
IS550-30-1 DT400 Tee Connector Installation Instructions
IS550-31-1 DPC400 and DPC436 Connecting Plug Installation Instructions
IS550-60-1 DTS1242 Bolted Tee Connector - Interface C Installation Instructions for Single Core Cable with Copper Wire Screen and Outer Sheath
IS550-61-1 DTB1242 Bolted Companion Tee Connector - Installation Instructions for Single Core Cable with Copper Wire Screen and Outer Sheath
CP1203 42 kV 1250 A Screened Deadbreak Separable Connector System Certified Test Report
Document Number Reference Literature
94034 E200 Fluid Material Safety Data Sheet
Document Number Title
S328-10-1 UltraSIL™ Polymer-Insulated D-73P Disconnect and D-73P3 Bypass Switches Installation Instructions
R328-10-1 D-73P Switch Cross Reference Information to D-73 Switch

Documents avaliable on CooperPowerCentral.com

Authentication is required.

Document Number Title
Service Literature
S1120-67-1 Local Computer Platform (LCP) Installation Guide-Version 1.0
S1150-10-1
(Discontinued)
Cellular OutageAdvisor Commissioning and Installation Instructions
S1150-10-2
(Discontinued)
OutageAdvisor Variable Trip Current Reset Faulted Circuit Indicator Supplemental Information
S1150-10-3
(Discontinued)
VARAdvisor Capacitor Bank Neutral Monitor (CBNM) Commissioning and Installation Instructions
S1160-80-1 CBC-8000 Control Installation Manual
S1150-20-1 GridAdvisor™ Series II smart sensor installation instructions
Reference Literature
B1100-09049 SMP I/O Datasheet
R1160-80-1 Capacitor Bank Control Serial Communications (DNP3 Data Points)
R1150-20-1 Communications Point Data Base for Communications Protocol DNP3
Technical Notes
B1100-09060 SMP Gateway Malware Protection
B1100-09091 SMP Gateway and Conitel RTUs
B1100-09059 IEC 61850-Based Substation Integration Solutions
B1100-09060 Using SMP Gateway to Securely Access Substation PCs
B1100-09021 Meeting NERC Requirements
B1100-09008 Redundancy Options with the SMP
White Papers
W1180-11035
Maximizing Protection Coordination with Self-Healing Technology
WP 083005EN Making sense out of Smart Grid cyber security standards
  An Introduction to Cryptography as Applied to the Smart Grid, presentation
  Enhancing Systems Stability Using Synchrophasors, presentation
  Implementing a substation abstraction model, presentation
  Implementing a substation abstraction model, presentation
  Securing Distribution Automation, presentation
  Designing a new IEC 61850 substation architecture, presentation
  2010 and Beyond, a new Odyssey for the “Grid”
  Open Enterprise Architectures for a Substation Password Management System
  Estimating of Engineering Costs When Using 61850 and GOOSE Messaging, presentation
  Business Benefits of Implementing a New Hydro-Electric Plant Control System
  Meeting IED Integration Cyber Security Challenges
  Intelligent Electronic Device Data Extraction at Hydro One
  Adding Intelligence to Substations and Distribution Lines
  Hidden Challenges in the Implementation of 61850 in Larger Substation Automation Projects
  How to Integrate NERC CIP Requirements in an Ongoing Project, presentation
  A Case Study: How a utility Automated and Integrated Automated and Integrated Data/Control for 4000 Pole for 4000 Pole-Top Top Switches and Protection Relays, presentation
  Optimizing Substation Automation by Using IED Data in an Intelligent Gateway
  Making the Most Out of Substation IEDs in a Secure, NERC Compliant Manner
Document Number Service Literature
S320-50-1 S.T.A.R. Faulted Circuit Indicator Type LV Installation Instructions
S320-60-1 S.T.A.R. Faulted Circuit Indicator Type ER Installation Instructions
S320-65-1 S.T.A.R. FCI Delayed Reset Instructions
S320-42-2 S.T.A.R. Fiber Optic Cable Installation Instructions
S320-70-1 S.T.A.R. FCI Manual Reset Installation
S320-75-1 S.T.A.R. FCI Current Reset Installation
S320-80-1 Hot Line Voltage Indicator Installation Instructions
S320-40-1 S.T.A.R. Faulted Circuit Indicator Type TPR Installation Instructions
S320-42-1 S.T.A.R. Pathfinder Variable Trip TPR Faulted Circuit Indicator Installation Instructions
S320-50-2 S.T.A.R. Faulted Circuit Indicator Remote Display Adapter Bracket Installation Instructions
S320-77-1 S.T.A.R. Pathfinder Variable Trip Current Reset Faulted Circuit Indicator Installation Instructions
S320-62-1 Discontinued-S.T.A.R. PATHFINDER Variable Trip Electrostatic Reset Type Faulted Circuit Indicator Installation Instructions
CP0601 Competitive Comparison of Electrostatic-Reset Faulted Circuit Indicators
CP9915 S.T.A.R. Faulted Circuit Indicator Test Point Variable Trip S.T.V.T. Test Report
S320-95-1 S.T.A.R. Faulted Circuit Indicator Programmable Delayed Reset Type SDOH Installation Instructions
Document Number Service Literature
S275-10-1 Installation & Operation Instructions of Type CI Interrupter
S275-10-3 Maintenance of Type CI Interrupter (Above S/N 1000)
S275-20-1 Installation of Operation Instructions of Type CM Fault Interruupter with Manual Operators & Accessories
S260-01 through S280-01 Distribution Switchgear Parts Guide
Document Number Service Literature
S240-34-2 Single-Phase MagneX Interrupter Retrofit Float Kit, MXFLOATKIT, Installation Instructions
S240-40-2 Sidewall-Mounted and Cover-Mounted Bay-O-Net Fuse Assembly Installation Instructions
S240-97-1 200 A Fused Loadbreak Elbow Connector Replacement Fuse Installation Instructions
S240-97-1EA Instrucciones de Instalacion para Reemplazo de Fusible del Conectador Tipo Codo Portafusible para Operacion con Carga de 200 A Español de América
S240-97-1P Instrucoes para Instalacao de Fusivel em Terminal Desconectavel Cotovelo com Porta Fusivel para Operacao em Carga de 200 A
S240-97-2 200 A Fused Loadbreak Elbow Connector Shorting Bar (Solid Link) Installation Instructions
S240-97-2EA Instrucciones de Instalacion Barra para Puenteo (Enlace Solido) para el Conectador Tipo Codo Portafusible para Operacion con Carga
S240-34-1 Single-Phase MagneX Interrupter Installation Instructions
S240-64-1 Companion II Back-up Current-Limiting Fuse Installation Instructions
S240-67-1 Tandem ELF Current-Limiting Dropout Fuse Installation Instructions
S240-70-1 EL Bay-O-Net Current-Limiting Fuse Installation Instructions
S240-80-1 ELG Current-Limiting Power Fuse Installation Instructions
S240-63-1 Direct-Connected Capacitor Fuse Installation Instructions
S240-92-1 Edison Modular Fuse Installation Instructions
S240-71-1 ELF-LR Current-Limiting Fuse Installation Instructions
S240-61-1 Current-Limiting-Type NXC (C-Rated) Fuse Installation Instructions
S240-62-1 Current-Limiting NX Fault Guard Tool Operating Instructions
S240-93-1 Automatic Sectionalizing Link Installation Instructions
S240-94-1 Cooper CMU Expulsion Power Fuse Installation Instructions
S240-33-1 Two- and Three-Phase MagneX Interrupter Installation Instructions
S240-40-3 Bay-O-Net Fuse Re-fusing Installation Instructions (5000023080)
S240-50-1 ELSP Current-Limiting Backup Fuse Installation Instructions (5000050268)
S240-56-1 X-Limiter Full Range CL Fuse
S240-64A-1 K-Limiter Backup CL Fuse
S240-82-1 ELSG Power Fuse (5000050635)
S240-84-1 X-Limiter Hinge-Mount for S & C SMD-20 Installation Instructions
S240-86-1 Epoxy Encapsulated X-Limiter Fuse
S240-66-1 ELF Current-Limiting Dropout Fuse Installation Instructions
S240-84-2 X-Limiter Hinge-Mount for S & C SML-4Z Fuse Mounting & Installation
S240-31-1 Internal Cartridge Fuse (5000050712)
S240-72-1 EL Bay-O-Net Fuse (5000036042)
S240-60-2 Installation of Plate Mounted NX Fuses
S240-60-4 Mounting Hinged FX Fuse Contact Assemblies
S240-75-1 (Discontinued) ELST Fuse (5000050532)
S240-84-3
(Discontinued)
X-Limiter Hinge-Mount for S&C SM-20 Fuse Mounting Assembly & Installation
S240-20-11
(Discontinued)
Type S1 Expulsion Fuse Cutout Assembly Instructions
Document Number Reference Literature
R240-000-1 Pad-Mounted Transformer Fusing Philosophies
R240-64-1 K-Mate Fuse from Hubbell Power Systems, Inc. / Companion II Fuse from Cooper Power Systems Cross Reference Guide
R327-40-10 Kearney Fuse Links-Coordination Chart for Type K with Type X Fuse Links
R327-40-11 Kearney Fuse Links-Coordination Chart for Type QA with Type X Fuse Links
R327-40-12 Kearney Fuse Links-Coordination Chart for Type K Fuse Links
R327-40-3 Kearney Fuse Links-Coordination Chart for Type 200 Fuse Links
R327-40-4 Kearney Fuse Links-Coordination Chart for Type KS Fuse Links
R327-40-6 Kearney Fuse Links-Coordination Chart for Type T Fuse Links
R327-40-7 Kearney Fuse Links-Coordination Chart for Type T with Type X Fuse Links
R327-40-8 Kearney Fuse Links-Coordination Chart for Type N (200) with Type X Fuse Links
R327-40-9 Kearney Fuse Links-Coordination Chart for Type KS with Type X Fuse Links
R240-30-7 Coordination Tables for K, QA, S, & T Links with D-Link
R327-40-1 Recommended Type D Link Primary Fusing for Distribution Transformers
R327-40-2 Recommended Types X and KS Link Primary Fusing for Distribution Transformers
R240-45-1 Single-Phase CSP Transformer Bay-O-Net Current Sensing Fuse and ERMCO Secondary Breaker Correlation Chart
FAQ MagneX MagneX Interrupter and How to Determine Watts Loss
CP0507 S&C Electric SMU-20 and Cooper Power Systems CMU-20 Power Fuse Cross Reference
R240-30-6 Recommended D-Link Primary Fusing for Distribution Transformers
97043 Current-Limiting Fuses & Power Quality
96048 Transformer Fusing Protection & Coordination
96025 Southern Version (96008 Special)
96008 Current-Limiting Fuse Improves Public Safety & Power Quality
R240-30-8 Coordination Tables of CS & DS BON Fuses with K & T Links
93033 Application Solutions Provided with the ELF Current-Limiting Dropout Fuse
R240-66-1 ELF Current-Limiting Dropout Fuse Coordination Tables with Protecting Fuse Links
R240-66-2 ELF Current-Limiting Dropout Fuse Coordination Tables with Protected Fuse Links
91027 Developing A Fusing Schedule
92024 The D-Link Fuse-New Ratings and Explanations of Surge Durability, Protective Equipment Update
TD311 Comparison of Tin and Silver Fuse Links
90016 D-Link Brochure
89012 Tin vs. Silver fuse Links - A Comparison
81027 Oil-Immersed Expulsion Fuses
R240-30-3 Coordination of Fuse Links with Oil Circuit Reclosers
78018 Current-Limiting Voltage Selection
R240-60-13 Recommended Transformer NX Fuse Applications
R240-30-1 Expulsion Fuse Links Transformer Protection
R240-62-1 NX Fault Guard Tool Test Data Certification
R240-60-2 Minimum Melt Characteristics of NX Fuses
R240-60-5 Maximum Total & Minimum Melt I2t Comparison of NX Fuse
R240-60-7 Parallel Operation of NX Fuses
R240-30-2 Coordination Tables for K, T, H, & N Links
R240-30-5 Fuse Links for Carrying Lightning Surges
R240-60-11 NX Fuses with Arc Strangler Switch Equipment Specs
R240-60-6 NX Fuse Mounting Clearances
CP0406 15 kV and 25 kV Class Encapsulated Fuse Certified Test Report
CP0603
Edison Modular Fuse Cross Reference Chart
CP0006 ELST Fuse to ELSG Fuse Cross Reference
CP8802 Basic MagneX Interrupter Operation
CP9714 Cross-Reference Chart-NX Companion II
CP9703 Cross Reference NXII/ELX Clip Style & Hinged Style Types
CP8209 Economics of Fusing Three-Phase Deadfront Pad-mounted Transformers
CP7734 What the Rating System on Fuses Mean
CP8714 MagneX Interrupter  Philosophies
CP8806 MagneX Losses
CP8809 MagneX TCC at Various Temperatures
R240-48-1 Dual Element Bay-O-Net Fuse Link Cross Reference
Document Number Time Current Curves
R240-91-166 8.3 and 15.5 kV Fused Loadbreak Elbow Connector Replacement Fuse Time Current Curve
R240-91-167
ELSP 8.3/9.9 kV Time Current Characteristic Curves
R240-91-168
ELSP 15.5/17.2 kV time Current Characteristic Curves
R240-91-169 ELSP 23.0 kV Time Current Characteristic Curves
R240-91-46 Tandem ELF Current-Limiting Dropout Fuse Curves
R240-91-164 23.0 kV Class 150 A Windfarm ELSP Time Current  Curve
R240-91-165 Companion II Fuse Time Current Characteristic Curves
R240-91-161 Edison Modular Fuse 5.5 and 8.3 kV Class Time Current Curve
R240-91-162 Edison Modular Fuse 15.5 and 17.2 kV Class Time Current Curve
CTTCC205B00 15.5 JOE E-Rated Current-Limiting Power Fuse Time Current Curve
CTTCC207B00 5.5 JOE E-Rated 2" Diameter Current-Limiting Power Fuse Time Current Curve
CTTCC208B00 5.5 JOE E-Rated 3" Diameter Current-Limiting Power Fuse Time Current Curve
CTTCC209B00 15.5 JOE E-Rated 2.0" Diameter Current-Limiting Power Fuse Time Current Curve
R240-91-47 8.3/13.7 kV and 17.2/23 kV ELF-LR Fuse Time Current Curve
R240-91-48 17.2/23 kV ELF-LR Current Limiting Fuse Peak Let-Thru Current Versus Available RMS Current Time Current Curve
R240-91-151 CMU 712XXX, 713XXX & 714XXX Fuse Time Current Curve
R240-91-152 CMU 612XXX, 613XXX, 614XXX Fuse Time Current Curve
R240-91-153 CMU 702XXX, 703XXX and 704XXX Fuse Time Current Curve
R240-91-154 CMU 712XXX Fuse Time Current Curve
R240-91-155 CMU 612XXX Fuse Time Current Curve
R240-91-156 CMU 702XXX Fuse 17 kV Time Current Curve
R240-91-157 CMU 713XXX and 714XXX 27 kV and 38 kV Time Current Curve
R240-91-158 CMU 613XXX and 614XXX 27 kV and 38 kV Time Current Curve
R240-91-159 CMU 703XXX and 704XXX 27 kV and 38 kV Time Current Curve
R240-91-302 Minimum and Maximum Trip Curves for Three-Phase MagneX TCC
R240-91-73 Min. Melt 23.0 kV Mini Mid-Range & Multi-Coil ELSP Backup Type Oil Fuse Curve
R240-91-71 Min. Melt 8.3kV Mini, Mid-Range, & Multi-Coil ELSP Backup Type Oil Fuse Curve
R240-91-72 Min. Melt 15.5 kV Mini Mid-Range & Multi-Coil ELSP Backup Type Oil Fuse Curve
R240-91-310 Minimum Trip Curves for MagneX
R240-91-34 23 kV NX Fuse curve
R240-91-35 27 & 38 kV NX Fuse Curve
R240-91-52 CS Cartridge 718 & 719C Fuse Links Curve (RTE 1551B & 2B)
R240-91-55 DS Cartridge 722, 723, 628 & 629 Fuse Link Curve(RTE 1555B & 56B)
R240-91-12 FL1A Tin Series Average Melt Fuse Curve
R240-91-15 S-Tin Link Fuse Curve
R240-91-30 4.3 kV NX Fuse Curve
R240-91-32 8.2 kV NX Fuse Curve
R240-91-33 15.5 kV NX Fuse Curve
R240-91-9 N-Tin Link Fuse Curve
R240-91-6 ET-Tin Link Fuse Curve
R240-91-7 EH-Link High Surge Fuse Curve
R240-91-8 C-Tin Link Fuse Curve
R240-91-4 K-Silver Link Fuse Curve
R240-91-5 EK-Tin Link Fuse Curve
R240-91-1 K-Tin Link Fuse Curve
R240-91-2 T-Tin Link Fuse Curve
R240-91-53 Minimum Melt High Amp Transformer Overload Link Fuse Curve(65, 100, 125A)
R240-91-16 D-Link (RTE 38888 & 89B) Fuse Curve
R240-91-38 15.5 kV NXC Capacitor Fuse Time Current Curve
R240-91-39 23 kV NXC Capacitor Fuse Curve
R240-91-43 15 kV ELF Dropout Fuse Curve(RTE 39211 & 13 B)
R240-91-44 23.0 kV ELF Dropout Fuse Curve
R240-91-58 Type FL8R and FL23R Expulsion Fuses Time Current Curves
R240-91-70 8.3, 15.5 & 23 kV ELX Fuse Curve (RTE 3437790B & 91B)
R240-91-85 2 Inch Diameter 8.3, 15.5 & 23 kV ELSG Fuse Curve (RTE 39051 & 52B)
R240-91-88 8.3, 15.5 & 23 kV ELSG Fuse Curve (RTE 39102 & 03B)
R240-91-89 23 kV ELSG Fuse Curve (RTE 39217 & 18B)
R240-91-90 5.5, 8.3 & 15.5 kV ELG (RTE 38046 & 45B)
R240-91-91 23.0/25.8 kV ELG
R240-91-113 8.3 kV and 15.5 kV K-Limiter Backup Fuse Time Current Curve
R240-91-57 Dual Element Bay-O-Net Fuse Link (RTE 39029 & 30B)
R240-91-109 8.3, 15.5 & 23 kV X-Limiter Full Range Fuse Curve(CTI 301M & 301C)
R240-91-42 8.3 kV ELF Dropout Fuse Curve (RTE 39106 & 07B)
R240-91-76 15.5 kV ELS Fuse Curve (RTE 38286 & 87B)
R240-91-77 23 kV ELS Fuse Curve (RTE 38288 & 89B)
R240-91-86 8.3 & 15.5 kV ELSG 3 inch Diameter Fuse Curve (RTE 39053 & 54B)
R240-91-87 23 kV ELSG Fuse Curve (RTE 38452 & 53B)
R240-91-49 8.3, 15.5, and 34 kV ELF Current-Limiting Fuse Peak Let-Thru Current vs RMS Current
R240-91-75 8.3 kV ELS Fuse Curve (RTE 38284 & 85B)
R240-91-50 CS Bay-O-Net Fuse Link Curve(353C) (RTE 01553 & 54B)
R240-91-51 DS Bay-O-Net Fuse Link Curve(358C) (RTE 15517 & 58B)
R240-91-61 8.3 kV ELSP (RTE 04829 & 30B)
R240-91-64 15.5 kV ELSP Oil Immersible Current Limiting Fuse TCC (RTE 04831 & 32B)
R240-91-67 23 kV ELSP (RTE 04333 & 34B)
R240-91-60 8.3 kV Mini-ELSP (RTE 38611 & 12B)
R240-91-62 8.3 kV High Amp ELSP Fuse Curve (RTE 38644 & 45B)
R240-91-63 15.5 kV Mini-ELSP Fuse Curve (RTE 38613 & 14B)
R240-91-65 15.5 kV High Amp ELSP (RTE 38646 & 47B)
R240-91-66 23 kV Mini-ELSP (RTE 38615 & 16B)
R240-91-68 23 kV High Amp ELSP (RTE 38648 & 49B)
R240-91-82 8.3 kV Mid-Range ELSP Fuse Curve (RTE 39043 & 44B)
R240-91-83 15.5 kV Mid-Range ELSP Fuse Curve (RTE 39045 & 46B)
R240-91-84 23 kV Mid-Range ELSP Fuse Curve (RTE 39047 & 48B)
R240-91-112 Unitized X-Limiter Time Current Curve
R240-91-150 X-Limiter Hinger Fuse Time Current Curve
R240-91-37 8.3 kV NXC Capacitor Fuse
R240-91-3 H-Link, High Surge Fuse Curve
R240-91-105 4.3 kV X-Limiter Full Range Fuse Time Current Curve
R240-91-106 4.3 & 5.5 kV X-Limiter Full Range Parallel Mounted Fuse Time Current Curve
R240-91-107 5.5 kV X-Limiter Full Range Fuse Time Current Curve
R240-91-110 8.3, 15.5, 23 kV X_Limiter Full Range Parallel Mounted Fuse
R240-91-130 8.3, 15.5, 23 kV X-Limiter Full Range "E" Rated Fuse Time Current Curve
R240-91-56 Isolation Link (RTE1559B)
R240-91-111 8.3, 15.5 & 23 kV X-Limiter DW Fuse Curve(CTI 308M & 308C)
R240-91-31 5.5 kV NX Fuse Curve
Document Number Test Reports
CP9716 Companion II 8.3, 17.2 and 23.0 kV 12 K - 40 K Back-up Current-Limiting  Fuse Certified Test  Report
CP0508 Faulted Circuit Interrupting Tests on Type CMU Power Fuses Certified Test Report
CP0509 Faulted Circuit Interrupting Tests on Type CMU Power Fuses Test Report
CP0510 Faulted Circuit Interrupting Tests on Type CMU Power Fuses
CP0511 Temperature Rise Tests Type CMU Power Fuses Certified Test Report
CP0602 Cross Reference: CMU Power Fuse and Eaton DBU Fuses
CP0901 Interruption Testing Performed on 23kV 150A (3545150M75M) ELSP Backup CL Fuse in Series with an ABB 35kV #9 (345B995G27) Protective Link Used on 34.5kV Three-Phase Delta Transformers
CP1010 Design Tests for the Cover-Mounted Bay-O-Net Fuse Assembly Certified Test Report
CP1101 ELSP 8.3-23 kV Certified Test Report
Document Number White Papers
W240-10006 Fuse Coordination and Protection for 35 kV Delta Transformer Systems
IEEE-006 Application of Current-Limiting Fuses in Distribution Systems
IEEE-007 Considerations in the Selection of Primary Overcurrent Protection for Three-Phase Transformers
IEEE-003 CL Fuses Address Safety & Power Quality Concerns
IEEE-001 CL Fuses on Pole Type Transformers
Document Number Service Literature
S325-40-1 Load Pickup Clamp Assembly for 15 kV Systems, 300 A Maximum Installation and Maintenance Instructions (Kearney K-SEC 200)
S327-30-1 UltraSIL and Porcelain Type L Open Distribution Cutout Installation Instructions (Replaces S240-21-1)
KS010-01-1 Kearney Open Distribution Cutouts Type HX Installation Instructions
KS1.1-01-1 HX-CB Loadbreak Fuse Cutout Installation Instructions
KS200-01-1 200 A 15/25/35 kV Grounding Elbow Installation Instructions
Document Number Reference Literature
R325-30-1 Kearney Hotstick Catalog Number Cross Reference  - Past and Present
R327-40-4 Kearney Fuse Links-Coordination Chart for Type KS Fuse Links
R327-40-7 Kearney Fuse Links-Coordination Chart for Type T with Type X Fuse Links
R327-40-8 Kearney Fuse Links-Coordination Chart for Type N (200) with Type X Fuse Links
R327-40-10 Kearney Fuse Links-Coordination Chart for Type K with Type X Fuse Links
R327-40-11 Kearney Fuse Links-Coordination Chart for Type QA with Type X Fuse Links
R327-40-12 Kearney Fuse Links-Coordination Chart for Type K Fuse Links
R327-40-3 Kearney Fuse Links-Coordination Chart for Type 200 Fuse Links
R327-40-6 Kearney Fuse Links-Coordination Chart for Type T Fuse Links
R327-40-9 Kearney Fuse Links-Coordination Chart for Type KS with Type X Fuse Links
R327-40-1 Recommended Type D Link Primary Fusing for Distribution Transformers
R327-40-2 Recommended Types X and KS Link Primary Fusing for Distribution Transformers
R327-01-1 Type L Interchangeable Cutouts, Mounting Frames, Fuseholders, and Disconnect Blades Cross Reference
TD311 Comparison of Tin and Silver Fuse Links
89012 Tin vs. Silver Fuse Links - A Comparison
Document Number Test Reports
CP9618 Type L Open Porcelain and Polymer Distribution Cutout Certified Test Report
KCP-0001 Kearney M-Force Switch Test Report
Document Number Time-Current Curve
K-51000AB Kearney Type T TCC
K-124080AB Kearney Type 124080 Dual Element TCC
K-11000AB Kearney Type N (200) TCC
K-21000AB Kearney Type KS TCC
K-31000AB Kearney Type K TCC
K-41000AB Kearney Type X TCC
K-6010-32AB Kearney Type QA TCC
K-124092AB Kearney Type 124092 Dual Element TCC
K-124090AB Kearney Type 124090 Dual Element TCC
K-SQ AB Kearney Type SQ TCC
Document Number Service Literature
S500-10-8 200 A 15 kV and 25 kV Class Elbow with Integral Jacket Seal for Use on Tape and Wire Sheilded Cable Installation Instructions
S500-110-1 Fused Loadbreak Elbow Connector Installation Instructions
S500-110-1EA Instrucciones de Instalacion del Conectador Tipo Codo Portafusible para Operacion con Carga Español de América
S500-110-1P Instrucoes de Instalacao de Terminal Desconectavel Cotovelo com Porta Fusivel para Operacao em Carga
S500-10-2 200 A 15 kV Class Elbow with 5 kV Cable Adapter and Optional Integral Jacket Seal Installation Instructions
S500-10-7 200 A 15 kV and 25 kV Class Elbow with Optional Integral Jacket Seal Installation Instructions
S500-41-3 200 A 35 kV Class Loadbreak Elbow Retrofit Instructions from Single-Phase Solid Probe and Three-Phase Probe to Single-Phase QuickMake Probe and Tan Cuff
S500-41-2 200 A 35 kV Class Loadbreak Elbow Retrofit Instructions from Single-Phase QuickMake and Solid Probe to Three-Phase Probe and Purple Cuff
S500-12-1 200 A 15 & 25 kV Loadbreak Bushing Insert Installation Instructions (5000050749)
S500-15-1 200 A Loadbreak Junction 15, 25 & 35 kV Class Installation Instructions (5000050559)
S500-20-1 200 A 15 kV and  25 kV Class Insulated Bushing Well  Plug (5000033038)
S500-41-1 200 A 35 kV Class "LE" Series Elbow Installation Instructions
S500-14-1 200 A 15, 25, and 35 kV Class Portable Feedthru Installation Instructions
S500-21-1 200 A 15, 25, and 35 kV Class Insulated Protective Cap Installation Instructions (Replaces S500-65-1)
S500-22-1 15, 25 & 35 kV Insulated Standoff Bushing
S500-001-1 Coppertop Compression Connector Crimp Chart
S500-13-1 Loadbreak Rotatable Feedthru Insert Instructions (5000050710)
S500-90-1 200 A Cable Jacket Seal
S500-11-1
(Discontinued)
200 A 15 kV and 25 kV Class Injection Elbow Installation Instructions - Discontinued Product
S500-45-1 200 A 35 kV Class Single-Phase QuickMake Probe Replacement Installation Instructions
S500-51-1 200 A, 35 kV Class Loadbreak Junction Installation Instructions
Document Number Reference Literature
R500-01-1 15, 25, 28 kV Class Loadbreak Elbow Connector and 25 kV POSI-BREAK Loadbreak Elbow Connector ICEA Cross Reference Data
B100-02034 Cooper / Elastimold Cross Reference Guide
Document Number Test Reports
CP9141 The Cooper Power Systems Multi-Stress Test
Document Number Test Reports
CP0604 Cross Reference Junction Bars

No technical documents available.

For additional technical information about products that comprise a MITS, please refer to that section.

Document Number Service Literature
S800-65-2 Two-Position Sidewall (Horizontal) and Cover (Vertical) Mounted Loadbreak Switches Installation Instructions
S800-39-1 35 kV Three-Phase Bushing Retrofit Kit Installation Instructions
S800-46-1 600 A 15,  25, and 35 kV Class Deadbreak PUSH-OP Apparatus Bushing Installation Instructions
S800-35-2 High-Voltage Primary Bushings Installation Instructions
S800-57-1 100 A Tap Changer - Cap/Wrench, Lever or Hotstick Operable Handles Installation Instructions
S800-70-1 50 A 2:1 Series Multiple (Dual Voltage) - Cap/Wrench, Lever or Hotstick Operable Handles Installation Instructions
S800-72-1 150 A Series Multiple (Dual Voltage) - Cap/Wrench, Lever or Hotstick Operable Handles Installation Instructions
S800-75-1 300 A Externally Operated Series Multiple (Dual Voltage) Switch Installation Instructions
S800-64-2 Sectionalizing Switch Installation Instructions
S800-60-1 300 A Externally Operated Tap Changer Switch Installation Instructions
S800-16-1 1.2 kV Secondary Bushing Installation Instructions
S800-51-1 Under-Oil Arrester Disconnector Installation/Operation Instructions(5000050771)
S800-34-2 Removable Replaceable Stud in Bushing Well (5000050753)
S800-64-1 Sectionalizing Switch (5000050062)
S800-58-1 Manual or Hotstick Operable, Padlockable 150 A Tap Changer Switch
Document Number Reference Literature
R800-65-1 Two-Position Sidewall (Horizontal) and Cover (Vertical) Mounted Loadbreak Switches Cross Reference
Document Number Test Reports
CP8918 High Ampere Dual Voltage & Tap Changing Switches Certified Test Report
CP9228 MagneX Interrupter for Dual Voltage Transformers
CP9715 Tow Position Loadbreak Switch Used in a 46 kV 65 A Application Certified Test Report
CP1214 600 A 35 kV Class Deadbreak Bushing with Internal Ground Screen Certified Test Report
Document Number Service Literature
S230-10-1 Medium-Voltage, Single-Phase Capacitor Installation and Maintenance Instructions
S230-10-1F Haute tension, monophase
S230-10-1S Instructiones de instalacion y mantenimiento de Condesadores electricos monofasicos de alto voltaje
S230-20-1 Pole-Mount with Single-Phase Capacitors Installation Instructions
S230-20-1EA Montaje en Poste con Condensadores Monofasicos Instructive de Instalacion Español de América
S230-20-1F Condensateurs monophases installes sur des poteaux
S230-30-1 Installation of Block Banks Capacitors
S230-30-1S Instrucciones de instalación Bancos de Condensadores con fusibles externos
S230-30-3 Expulsion Fuse Installation Instructions
S230-30-3S Instructiones de Instalacion de Fusibles Tipo Expulsion
S230-30-4 Fuseless Block Banks Installation Instruction
S230-50-1 Edison™ Single-Phase Capacitor Switch
S230-55-1 Metal-Enclosed, Pad-Mounted Capacitor Banks Installation Instructions
S230-70-1 Metal-Enclosed Capacitor Bank Installation Instructions
Document Number Reference Literature
Edisol VI Edisol VI Material Safety Data Sheet
R230-91-1 Tank-Rupture TCC - EX Line
R230-91-2 Tank-Rupture TCC - Type EX- D
Kilovar Brief Issue 7 Partial Discharge Considerations in Capacitor Design
Kilovar Brief Issue 6 Harmonics & Capacitors - Dynamic Overvoltages
Kilovar Brief Issue 9 General Capacitor Fusing Criteria
Kilovar Brief Issue 2 Evaluating Today's All-Film Capacitors
Edisol XT Edisol XT MSDS
Kilovar Brief Issue 12 Individual Capacitor Fusing
Kilovar Brief Issue 22 When is a Compensating Unbalance Scheme Necessary?
Kilovar Brief Issue 20 Grounded Vs. Ungrounded Pole Mounted Capacitor Racks
Kilovar Brief Issue 21 Grounded Vs. Ungrounded Substation Capacitor Banks
Kilovar Brief Issue 19 Capacitor Tank Rupture Curve Coordination
Kilovar Brief Issue 17 Practical Considerations for Substation PCB Capacitor Changeout
Kilovar Brief Issue 16 Evaluation of Changes in Dielectric Stress Levels
Kilovar Brief Issue 15 Capacitor Technology Advancements Enhance Design of Large Capacitor Banks
Kilovar Brief Issue 13 The EX - 7 Cpacitor & High Energy Applications
Kilovar Brief Issue 11 Economics of Substation PCB Capacitor Changeout
Kilovar Brief Issue 8 Capacitor Reliability: Short-Term Testing & Product Life
Kilovar Brief Issue 5 Harmonics & Capacitors - Applying Capacitors in the Harmonics Environment
Kilovar Brief Issue 4 Haromonics & Capacitors - Effects of Capacitors in the Harmonics Environment
Kilovar Brief Issue 3 Harmonics & Capacitors - Source of Harmonics
Kilovar Brief Issue 1 Overvoltages on Capacitor Banks - De-energization Transients
71011 Economics & Application - Shunt Capacitors on Utility Systems
R230-90-1 ABC's of Capacitors Power-Factor Correction
R230-30-3 Calculation of Inrush Currents in Single- and Multi-Step Capacitor Bank Installations
Document Number Service Literature
Issue Date
  None Available  
Document Number Service Literature
S280-104-1 Form 4D Control Instructions
S280-42-1 NOVA15, NOVA27 & NOVA38 kV Reclosers Installation & Operation Instructions
S280-42-1F Types NOVA 15, NOVA 27 et NOVA 38; triphases, commandes par microprocesseur; instructions d'installation et d'utilisation (French)
S280-42-1S Tipos NOVA 15, NOVA 27 y NOVA 38; trifasicos controlados por microprocesador; instrucciones de instalacion y funcionamiento (Español de América)
S280-70-13 Form 6 Microprocessor-Based Recloser Control Automatic Source Transfer (AST) Application Instructions
S280-77-7 Microprocessor-Based Recloser Control Battery Charger Kit KME4-711
S280-79-14 KA43ME7001 Portable Lead Acid Battery Charger For Form 4C, Form 5, Form 6 and FXB Controls
S280-90-6 Electronic Control Battery Testing, Charging, and Replacement Instructions
S280-44-1 Types NOVA STS-15, NOVA STS-27, and NOVA STS-38 Single-Tank, Triple-Single, Electronically Controlled Recloser Installation and Operation Instructions
S280-42-2 Types NOVA TS-15 & NOVA TS-27 & NOVA TS-38 Triple-Single Electronically Controlled Recloser Installation & Operation Instructions
S280-79-12 Kyle form 5 LS/UDP and Form 5 LS/UDP DC NOVA Microprocessor-Based Recloser Controls Installation and Operation Instructions
S280-20-2 Type D, DV Single-Phase Recloser Maintenance Instructions
S280-70-11 Form 6 Recloser Control Disassembly, Reassembly, and Testing Instructions
S280-70-1+20000 Form 6 Rack Mount Recloser Control Installation & Operation Instructions (applies to serial numbers above 20000)
S280-70-3+10000 Form 6 Microprocessor-Based Pole Mount Recloser Control Installation and Operation Instructions (applies to serial numbers above 10,000) 
S280-70-3S Instrucciones de instalacion y funcionamiento del control de restauradores controlado por microprocesador Forma 6 de montaje en poste
S280-70-2+10000 Form 6 Microprocessor-Based Yard Mount Recloser Control Installation and Operation Instructions (applies to serial numbers above 10000) 
S280-17-1 Types Nova1-15 and NOVA1-27 Single-Phase, Electronically Controlled Recloser Installation and Operation Instructions
S280-17-4 NOVA<sup>1</sup> Ball-Target Replacement Kit Instructions
S280-78-3 Kyle Type FXB Microprocessor-Based Electronic Recloser Control Front Panel Programming Instructions
S280-10-1 Type H Single Phase Maintenance Instructions
S280-10-12 Types H, 3H, 4H, V4H, 6H and V6H Adjustable Control Valve Kits KA722H4-1, -2, and -3; Installation Instructions
S280-10-5 Maintenance of Type 6H & V6H Reclosers
S280-10-10 Plunger Return Spring Kit KA721H4 for Types 4H & V4H Reclosers Installation Instructions
S280-15-10 Types L, V4L, E, 4E, and V4E, KA785L10S, KA785L20S, KA785L30S and KA785L40S Automation Upgreade Kit Installation Instructions
S280-40-7 Types RXE and WE Maintenance Instructions
S280-70-10 Form 6-LS Pole Mount Control Instructions
S280-70-8 Form 6 Triple-Single/LS Pole Mount Control Instructions
S280-10-2 Types H, 4H, and V4H Recloser Non-Reclosing Head Assembly Kits KA729H and KA710H4 Installation Instructions
S280-70-14 Form 6 Triple-Single Rack Mount Recloser Control
S280-70-15 Form 6 Triple-Single Yard Mount Recloser Control
S280-70-7 Form 6 Triple-Single Control Installation Instructions
S280-85-17 Substation Frame KNOVA59-1 Assembly and Installation
Instructions
S280-85-16 KNOVA-54-3 & KNOVA 54-4 Pole Mounting Hanger Assembly and Installation Instructions
S280-85-2 Installation of KA146W5 Single-Phase Hanger; KA146W2 Tank Lifting Windlass
S280-10-11 Plunger Return Spring Kit KA704H6 For Types 6H & V6H Installation Instructions
S280-10-16 Types 3H & 6H Counter Replacement Kit KA701H3 Installation Instructions
S280-40-11 Type R, RE, W, WE Closing Solenoid Contactor Replacement Kit KA852R Installation Instructions
S280-77-1 Installation & Operating Instructions-Form 4C Type ME Control
S280-90-5 Slip-on Bushing CT Kits KA712L1S, KA712L2S, KA712L3S, and KA712L5S Installation
S280-70-2_10000 Form 6 Microprocessor-Based Yard Mount Recloser Control Installation and Operation Instructions (applies to serial numbers below 10000) 
S280-70-5 Form 6 Rack Mount Recloser Control KME6-1802, -1803, -1804 Mounting Kit Installation
S280-30-11 Calibrating KA864-R1 / KA864-R2 Time Delay Units (Four Curve)
S280-70-3_10000 Form 6 Pole-Mount Recloser Control Installation and Operation Instructions (applies to serial numbers below 10,000)
S280-77-11 Form 4C Control Protocol Conversion Kit
S280-80-11 Installation & Accessory Information Auxiliary Switch-KA369R
S280-80-14 Types R, W, WV, & RV KA869R and KA835W Trip Coils
S280-80-16 Operation Counter Replacement Instructions 
S280-70-1_20000 Form 6 Rack Mount Recloser Control Installation & Operation Instructions (applies to serial numbers below 20000)
S280-57-1 Type VSO12 and VSO16 Motor-Operated, Electronically Controlled Recloser Operation Installation Instructions
S280-85-7 KA126H3 and KA847W Surge Arrester Mounting Brackets Assembly and Installation Instructions
S280-10-13 KA 716L7001 Adjustable Control Valve Kit for Types L, E, 4E, V4E, and V4L Reclosers Installation and Adjustment Instructions
S280-10-8 Installation of Types E, 4E, V4E, H, 4H, V4H, L and V4L Reclosers
S280-10-8S Tipos E, 4E, V4E, H, 4H, V4H, L y V4L Instrucciones de instalacion y funcionamiento monofasico
S280-79-3 Form 5 and Form 5 LS RS-232/Fiber-Optic Accessory InstructionsForm 5 Standard/LS/UDP Controls, Fiber-Optic/ RS-232 Serial Communications Accessory Operation Instructions
S280-10-6 Types 4H Single-Phase and 6H Three-Phase Reclosers - Vacuum Interrupter Conversion Kits Installation Instructions
S280-15-8 KA715L1, KA715L2, KA715L3 Types L, E and 4E Sequence Selector Kit Installation Instructions
S280-30-1 Installation of Types W, WV27, WV38X, VW, VW27 & VWV38X Reclosers
S280-77-8 Form 4C Control Analog Current Metering Accessory
S280-78-1 Installation & Operation of Types FXA & FXB Control
S280-85-11 Installation of Pole Hangers to Recloser Mountings
S280-70-6 Form 6 Recloser Control KME6-1875-1, KME6-1875-2, and KME6-1875-3 Fiber Optic Converter Kit Instructions
S280-40-10 Mercury Switch to Microswitch Retrofit Kit KA349WE Installation Instructions
S280-40-2 Installation of Types VWE, VWVE27, VWVE38X, WE, WVE27 & VE38X
S280-42-3 Installation of Triple-Single NOVA Recloser Control
S280-10-14 Kyle Type 6H, Type V6H Three-Phase Reclosers Installation and Operation Instructions
S280-77-4 Form 4C, Microprocessor-Based Recloser Control Programming Guide
S280-85-13 KGN50E Pole-Mounting Hanger Assembly and Installation Instructions
S280-80-13 CT Field Modification Kit KA906R1
S280-25-6 Type E Recloser, Installation of Kit KA718E
S280-30-12 Types R, RV, W, and WV Three-Phase Reclosers, Installation of KA296R1S Lockout-Indicating Switch
S280-30-2 Type R Three-Phase Reclosers Maintenance Instructions
S280-79-1 Kyle Form 5 and Form 5LS/UDP Microprocessor-Based Recloser Control (swing-panel only) Instructions
S280-80-22 Types R, W Series Trip Coil Replacement Instructions; R Recloser KA801R Coils - S/N 2215-9000, W Recloser KA803W Coils -S/N. 1999 and lower
S280-85-1 Substation Frame KA89WV1 and Accessories Assembly and Installation Instructions
S280-10-7 Types 4H, V4H, 6H, and V6H KA705H4-1 and KA705H4-3 Plunger and Plunger Stop Kit Instructions
S280-16-1 Installation & Operation of Types VXE15 & VXE27 Electronically Controlled Single-Phase Reclosers
S280-40-6 Maintenance of Types VWE, VWVE Reclosers
S280-45-1 Type VSA12, VSA12B, VSA16, VSA20, & VSA20A Operation and Installation Instructions
S280-85-9 Mounting Bracket KA19H3 Assembly and Installation Instructions
S280-10-9 Maintenance of Type H Reclosers (above S/N 246405), Type 4H (above 69276) & V4H (above S/N 7543)
S280-75-1 Form 3A Type ME Electronic Control Installation, Operation, & Testing Instructions
S280-78-2 Types FX, FXA & FXB Controls Programmer's Software User's Manual
S280-77-9 Form 4C Control Standard and Automation Power Supply Replacement Instructions
S280-75-52 Type ME Control Remote Non-Reclose & Remote Ground Trip Block Maintained Contact Accessory KA2035ME2
S280-78-1S  Instrucciones de instalación, funcionamiento y mantenimiento de control de reconectador controlado por microprocesador tipos FXA y FXB
S280-79-4 Form 5 and Form 5/Triple-Single Recloser Controls Fiber-Optic and RS-232 Accessories Installation and Operation Instructions
S280-10-15 Types H, 3H, 4H, V4H, 6H, & V6H Series Trip Coil Kit KA83H Installation Instructions
S280-75-2 Basic Maintenance of Form 3 and Form 3A Type ME Controls
S280-79-2 Form 5 Microprocessor - Based Recloser Control Programming Guide
S280-77-13 Form 4C Front Panel Replacement Kit Instructions
S280-16-2 VXE Maintenance Instructions
S280-79-10 Kyle Form 5, Form 5UDP, Form 5DC NOVA Microprocessor-Based Recloser Controls (fixed panel) Installation and Operation Instructions
S280-79-2S Guía de programación de controles
de reconectadores por microprocesador Forma 5
S280-90-1 Vacuum Interrupters Withstand Test Information
S280-15-1 Type L Reclosers Maintenance Instructions
S280-77-10 Type LS Loop Sectionalizing Control Accessory For the Form 4C Recloser Control; Installation and Operation Instructions
S280-76-1 Operating Instructions-Type MET Electronic Recloser
S280-16-4 Operation Instructions For Type VXE Electronic Recloser Tester
S280-79-10P Controles Microprocessados para Religadores Kyle® Form 5, Form 5 UDP e Form 5 NOVA DC Instruções para Instalação e Operação
S280-79-4P Controles Form 5 e Form 5/Triple-Single para religadores Placas acessorias de Fibra Optica e RS232 Instrucoes para Instalacao e Operacao
S280-77-5 Form 4C Microprocessor-Based Recloser Control Battery Backup Instructions
S280-15-7 Maintenance of Type V4L, V4E Single-Phase
S280-78-2P Controles Microprocessados
Tipo FX, FXA e FXB Manual de Programação do Software
S280-15-9 Kyle Type L Recloser Kit Installation Instructions
KFE10002-P Tipo KFE e KFVE Controle Eletrônico Instruções de Instalação
KFE10003-P Tipo KFE Controle Eletrônico
Instruções de Manutenção
S280-30-10 KRW710V Vacuum Interrupter Replacement Kit Installation of Types VW, VWE, VWV, VWVE Reclosers
S280-40-9 Installation of WVA 103 Breather Valve & Cover
S280-85-5 KA662R Tank-Lifting Windlass Assembly & Installation Instructions
S280-75-35 Installation of KA450ME Replacement Battery in Type ME Control
S280-77-6 Form 4C Analog Current Metering Accessory-Design II KME4-88
S280-75-62 Closing Coil Control Fuse-Replacement Instructions
KFE10010-E Type KFVE and KFVME (27kV)
Bus Bar Kit KRK710-1
Installation Instructions
KFE10011-E Type KFE and KFME (15kV)
Bus Bar Kit KRK711-1
Installation Instructions
S280-77-2 Port to RS232 Interface-Form 4C Control
S280-77-3 Installation of Form 4C Fiber-Optic Digital Communication Accessory
KFE10004-E Export-Type KFE Recloser TCC
KFE10008-E Export, Installation-KFME & KFVME Reclosers
KFE10008-S Electrónicamente controlados
Tipos KFME y KFVME; trifásicos
S280-40-2S Export, Installation W-Group Electronically Controlled Reclosers (Spanish)
S280-16-3 VXE SCADA Accessory Installation Instructions
KFE10002-E Export, Installation-KFE Recloser
S280-45-5 Maintenance of Types VSA12, VSA16 & VSA20/800
S280-40-8 Maintenance of Recloser Types RVE (S/N 220 & above) & WVE (S/N 1000 & above)
S280-40-5 Maintenance of Early Type RVE Reclosers
KFE10007-E Export-Type KFME Recloser TCC
KFE10005-E Export-Type KFE Recloser TCC
S280-30-8 Maintenance of Type RX Reclosers (S/N 679 & above) & W Reclosers (S/N 7334 & above)
S280-30-9 Maintenance of Type RV Reclosers (S/N 4111 & above) & WV Relcosers (S/N 901 & above)
S280-30-7 Maintenance of Type VW (above S/N 510), VWV27 (above S/N 144) & VWV38 Reclosers
S280-57-2 Maintenance of Type VSO Recloser
S280-25-4 Maintenance of Type 4E Recloser
KFE10003-E Export, Maintenace-KFE Recloser
S280-75-46A Maintenance of Form 3 and Form 3A Type ME Controls-Advanced Circuitry (pages 1-12) Go To S280-75-46B
S280-75-46B Maintenance of Form 3 and Form 3A Type ME Controls - Advanced Circuitry (pages 13-19) Go To S280-75-46C
S280-75-46C Maintenance of Form 3 and Form 3A Type ME Controls - Advanced Circuitry (pages 20-24)
S280-25-5 Maintenance of Type E Recloser (above S/N 52000)
KFE10002-S Instrucciones de Instalación del Reconectador de Vació del Tipo KFE Electrónicamente Controlado
S280-10-3 Types 4H and V4H Maintenance Instructions
S280-40-6S Tipos VWE y VWVE
Instrucciones de mantenimiento
S280-80-19 KA1169R closing Coil Transfer-Switch Accessory Operation
S280-20-1 Installation of Types D & DV Reclosers
76001E Export, Installation-KF Reclosers
S280-30-3 Maintenance of Early Type W Reclosers (Below S/N 7333)
S280-40-4 Maintenance of Early Type WE Reclosers
S77056E
(Discontinued)
Export, Maintenace-KF Reclosers
S260-01 through S280-01 Distribution Switchgear Parts Guide
S280-45-3 VSML Recloser Maintenance Instructions
S280-70-4
Form 6 Microprocessor-Based Recloser Control Programming Guide
S280-101-1
SPEAR™ Single-Phase Recloser System Installation and Operation Instructions
S280-80-23 Dielectric Grease Application to Recloser Cable Instructions
Document Number Reference Literature
73003 Type KF Recloser Time Current Curve
73004 Type KF Reclosers Time Current Curves
G280-104-1 Guideform Specification
KFE10004-E Type KFE Time Current Curves
KFE10005-E Type KFE Time Current Curves
KFE10007-E Type KFME Time Current Curves
R240-30-3 Coordination of Fuse Links with Reclosers
R280-10-1 Reclosers-Type E, H, 4H, V4H, (10) & Types 6H & V6H (30) Series-Trip Solenoid; Hydraulic Control Mechanism
R280-10-2 Reclosers-Types E, 4E & L Single-Phase, Series-Trip Solenoid; Hydraulic Control Mechanism
R280-90-1 Oil Specification & Tests-Distribution Switchgear
R280-90-2  Low-Voltage AC Testing of Hydraulic Reclosers
R280-90-4 Reclosers-Guide to Emergency Overload Capability
R280-90-5 Comparison of Reclosers & Breaker Standards
R280-90-6 Reclosers-Interpretations of Tolerance on Recloser Time-Current Characteristics
R280-90-7 Analysis of Distribution System Reliability & Outage Rates
R280-90-8 Basic Recloser Definition
R280-90-11 Form 4C Communications Point Data Base Data 2180 Revision 4 for Serial Communications Protocol Data 2179
R280-90-12 2179 Digital Communications Protocol for Form 4D, Form 4C, Form 5, Form 6, CL-5C, CL-5A, and CL-4C Controls
R280-90-13 Communications Point Data Base Data 2483 for Communications Protocol 2179 for use with Form 5, Form 5 UDP, Form 5 LS/UDP Recloser Controls
R280-90-14 Form 5 Control DNP 3.0 Protcol
R280-90-16 Form 4C Control DNP 3.0 Serial Communications
R280-90-17 Form 6 Control MODBUS Protocol Documentation
R280-90-18 Form 6 Control Communications Point Data Base for DNP3 Protocol
R280-90-19 Kyle Form 6 Control Comm Pt Data Base, Data 3024, Version 1.0
R280-90-25 Form 6 Control SCADA Communications Interoperability Data 3340 Rev. 0 for Communications Protocol IEC60870-5-104
R280-90-26 Form 6 Control SCADA Communications – Interoperability Data 3341 Rev. 0 for Communications Protocol IEC60870-5-101
R280-90-27 Form 4D Interoperability for Protocol IEC60870-5-104
R280-90-28 Form 4D Interoperability for Protocol IEC60870-5-101
R280-90-29 Form 4D Communications Point Data Base for Protocol 2179
R280-90-30 Form 4D Communications Point Data Base for MODBUS Protocol
R280-90-31 Form 4D Communications Point Data Base for Serial and Ethernet Protocol DNP3
R280-90-32 Form 4D Communications Point Data Base for Protocol IEC60870-5
R280-90-33 Interoperability for Protocol 61850
R280-90-34 Communications Point Data Base for Protocol 61850
R280-90-35
Communications Point Availability
R280-90-36 Communications Point Data Base Protocol IEC 60870-5
R280-90-37 Communications Point Data Base and Available Data Points for DNP3 for use with SPEAR Single-Phase Recloser Control
R280-91-1 Types H & 3H Recloser TCC
R280-91-2 Types 4H, V4H, PV4H, 6H, and V6H Recloser TCC
R280-91-3 Type L Recloser TCC
R280-91-4 Type D & DV Recloser TCC
R280-91-5 Type E (Below Serial 52000) Time-Current Curves
R280-91-6 Types R, RV, RX, VW, VWV, W, WV Recloser TCC Phase Trip
R280-91-7 Types R, RV, RX, VW, VWV, W, WV Recloser TCC Ground Trip
R280-91-8 Type 4E Recloser TCC
R280-91-9 Types R, RX, RV, W, WV, VW, VWV Time current Curves
R280-91-10 TCC Type E Recloser
R280-91-11 Types 3H, 6H, V6H Recloser TCC-Ground Fault Lockout Accessory
R280-91-12 Types, RX, RV, W, WV, VW, VWV Recloser TCC
R280-91-15 Types V4L, V4E Recloser TCC
R280-91-16 Type VXE TCC
R280-91-25 Type ME Electronic Recloser Control TCC
R280-91-26 Type PWE, PWVE, RE, RVE, RXE, SWE, SWVE, VEW, VWVE, WE, WVE Time Current curves
R280-91-27 Types VSA, VSAT, VSML, VSMT, VSO, Time Current Curves for Form 2, 3, and 3A Controls
R280-91-28 Types ME, MLE, MVE Time Current Curves
R280-91-29 Types CXE, CVE, CZE Time Current Curves
R280-91-31 Electronic Trip Control Time Current Curves
R280-91-33 Type RX, RV, W, VW, WV, VWV Time Current Curves
R280-91-34 Form 4A, Form 4C, Form 4D, Form 5, Form 5/TS, Form 6, Form 6-TS, FX, FXA, and FXB Recloser Controls Time-Current Curves
Document Number Service Literature
S270-21-2  Maintenance of Type GWC Sectionalizer and Schematics
S270-15-1 Installation of Types GN3E & GN3VE Sectionalizers
S270-20-3   Installation of Types GV & GW Sectionalizers
S270-30-1  Installation of TVS Sectionalizer
S270-20-2  Maintenance of Type GV Sectionalizer (Above S/N 1302)
S270-21-1  Installation of Types GWC Sectionalizers
S270-15-2  Maintenance of Types GN3E & GN3VE Sectionalizers
S270-20-5  Maintenance of Type GW Sectionalizer (S/N 2415 and Above)
S270-10-7 Maintenance of Type GN3 Form 2 Sectionalizer
S270-10-7S  Tipo GN3 (Forma 2)
Instrucciones de mantenimiento
S270-10-6  Maintenance of Type GH Form 2 Sectionalizer
S270-10-2
(Discontinued)
Mainentance of Type GN3 Form 1 Sectionalizer
S270-10-1
(Discontinued)
Maintenance of Type GH Form 1 Sectionalizer
S260-01 through S280-01 Distirbution Switchgear Parts Guide
Document Number Reference Literature
R1000-01-1 Sectionalizing Equipment Drawings
Document Number Service Literature
R700-15-1 EX II Splice Cross Reference
S700-15-1 15/25 kV Class EZ II Splice Installation Instructions (A, B, & C Cable Ranges Only)
S700-15-2 25/35 kV Class EZ II Splice
Document Number Test Reports
CP9141 The Cooper Power Systems Multi-Stress Test
Document Number Reference Literature
B100-02034 Cooper / Elastimold Cross Reference Guide
Document Number Service Literature
IS235-35-1EA  Apartarrayos IEC VariSTAR™ Con Envolvente UltraSIL™ 60099-4 para Sistemas MT a 36 kV Instrucciones de Instalacion y Servicio Español de América
IS235-35-1 UltraSIL™ Polymer-Housed VariSTAR™ Surge Arrester IEC 60099-4 for MV Systems to 36 kV Installation Instruction
IS235-81-1EA Insulating Bases and Surge Counter Installation Instructions Español de América
IS235-82-1 VariSTAR™ AZG2 Surge Arresters Installation Instructions
IS235-82-1EA  Varistar™ AZG2 Arrester Installation Instructions Español de América
IS235-83-1  VariSTAR™ AZG3 Installation 
IS235-83-1EA  VariSTAR™ AZG3 Installation Instructions Español de América
IS235-84-1 VariSTAR™ AZG4 Installation
IS235-84-1EA  Apartarrayos Tipo VariSTAR™ AZG4 Instrucciones para Instalacion y Mantenimiento Español de América
IS235-94-1 UltraSIL™ Housed VariSTAR™ Type U4 Surge Arresters Installation and Maintenance Instructions FOR USE WITH PRE-2013 U4 STATION-CLASS ARRESTERS WITH 15 DIGIT CATALOG NUMBERS
IS235-96-1 UltraSIL™ Polymer-Housed VariSTAR™ Types U2/U3 Surge Arresters Installation and Maintenance Instructions (Replaces IS235-92-1 and IS235-93-1) FOR USE WITH PRE-2013 U2 AND U3 STATION-CLASS ARRESTERS WITH 15 DIGIT CATALOG NUMBERS
IS235-97-1 UltraSIL™ Polymer-Housed VariSTAR™ Type U3 Surge Arresters Installation and Maintenance Instructions
S235-15-1 MOV Storm Trapper™ Secondary Class Sruge Arrester Installation Instructions
S235-16-1 VariSTAR™ Storm Trapper™  High Energy MOV Arrester Installation Instructions
S235-25-1 Surge Arrester/Open Link Cutout Combinations Installation
S235-25-2 STF (Flipper Fuse) Kit Installation
S235-26-1 Surge Arrester Interchangeable Fuse Cutout Combination Installation Instructions 
S235-35-1 UltraSIL™ Housed Distribution-Class MOV Arrester Installation Instructions
S235-35-2 UltraSIL™ Housed Distribution Class MOV BPL Coupler Installation Instructions
S235-35-3 UltraSIL™ Polymer-Housed Distribution-Class MOV BPL Coupler Installation Instructions
S235-40-2 VariSTAR™ Porcelain Type Distribution-Class MOV Arrester Installation Instructions
S235-55-1 15, 25, and 35 kV Class Standard M.O.V.E. and POSI-BREAK™ M.O.V.E. Elbow Arrester Installation Instructions
S235-58-1 Parking Stand Arrester Installation (5000050704)
S235-60-11 Porcelain-housed Distribution-Class Surge Arrester Assembly Instructions
S235-64-1 VariSTAR™ AZU Installation
S235-70-1 VariSTAR™ Type AZF Installation (VariSTAR Type AZF is Obsolete)
S235-71-1 VariSTAR™ AZR Installation (VariSTAR AZR Arrester is Obsolete)
S235-75-1 UltraSIL™ Polymer-Housed VariSTAR™ Type UI Intermediate-Class Surge Arrester (Discontinued Product)
S235-81-1 Insulating Bases and Surge Counter Instructions
S235-87-1 VariSTAR™ AZE Station-Class Arrester Installation
S235-88-1 UltraSIL™ Polymer-Housed VariSTAR™ Type US, UH, and UX  Station-Class Arresters Installation and Maintenance Instructions (Discontinued Product)
S235-89-1 UltraSIL™ Transmission Line Surge Arrester Installation Instructions (Engineered to Order Product)
S235-95-1 VariSTAR™ Type Composite Light-duty Under-oil (CLU) MOV Arrester Installation Instructions
S235-100-1 35 kV Class M.O.V.E. DirectConnect™ Elbow Arrester Installation Instructions
S235-102-1 UltraSIL Polymer-Housed VariSTAR Type UI Intermediate-Class Surge Arresters Installation and Maintenance Instructions
S235-103-1 UltraSIL Polymer-Housed VariSTAR Type US, UH, and UX Station-Class Surge Arresters Installation and Maintenance Instructions
S235-104-1 UltraSIL™ polymer-housed VariSTAR™ UXL high-strength station-class surge arresters installation and maintenance instructions
Document Number Reference Literature
IR235-98-1 Housing Codes Cross References for Type U3, Class 3 IEC Surge Arresters
IR235-99-1 Housing Codes Cross References for Type U4, Class 4 IEC Surge Arresters
R235-68-1 Elbow Arrester Cross Reference Tables
R235-90-1 Insulation & Arresters Terms & Definitions
R235-95-1 VariSTAR Type Composite Light-duty Under-Oil (CLU) MOV Arrester
R235-102-1 VariSTAR Surge Arrester Cross Reference Tables
TD245 Technical Specifications for VariSTAR MUS MOV Arrester Modules - IEEE Station/IEC Class 2
TD246 Technical Specifications for VariSTAR MUS MOV Arrester Modules - IEEE Station/IEC Class 3
TD247 Technical Specifications for VariSTAR MUS MOV Arrester Modules - IEEE Station/IEC Class 4
TD191 Arrester Fundamentals
TD192 Insulation Coordination
TD193 Type of Arresters & Their Construction
TD220 AZG Surge Arrester Rating Selection for Transmission & Station Applications
TD221 Technical Specifications for VariSTAR MUNS MOV Arrester Modules - 5 kA
TD222 Technical Specifications for VariSTAR MUHS MOV Arrester Modules - 10 kA
TD223 VariSTAR AZEH & AZEX Data Sheets
TD227 Technical Specifications for 5 kA, Normal-Duty 3 kV and 3.33 kV MOV Disks
TD228 Technical Specifications for 10 kA, Heavy-Duty 3 kV and 3.33 kV MOV Disks
TD230 Technical Specifications for 10 kA, Heavy-Duty 4.5 kV and 5 kV MOV Disks
TD231 Technical Specifications for 5 kA, Normal-Duty 4.5 kV and 5 kV MOV Disks
70026 Applying Traveling Wave Theory to Surge Protection
81022 Protecting Substation Equipment with MOV Surge Arresters
90044 VariSTAR Storm Trapper HE Test Report
93011 Surge Protection for UD Systems
92039 Storm Trapper High Energy Arrester Commonly Asked Questions & Answers on Low Voltage Circuit Protection
92025 Overvoltage Protection of AC Distribution Systems
91047 Conventional vs. CSP Transformers (LPT)
90051 LV Side Surge in Single Phase Transformer Systems
90027 Utility Savings with LV Arresters (PD Update 10)
90033 Conduction of Lightning Stroke Currents from Utility System to Load Devices
89031 VariSTAR Type AZL Heavy-Duty Distribution-Class Surge Arrester Certified Design Test Report
89016 Lightning (PD Update 9)
89015 Insulation Coordination Fundamentals (PD Update 8)
89014 Arrester Selection Criteria (PD Update 7)
89013 Surge Arrester Fundamentals (PD Update 6)
89012 Tin vs. Silver Links (PD Update No. 5)
89010 Underground Wye-Delta Transformer Banks (PD Update 3)
89009 Metal Oxide VariSTAR Technology (PD Update 2)
89008 Economics of MOV Applications (PD Update 1)
B100-02034 Cooper / Elastimold Cross Reference Guide
Document Number Test Reports
95062 UltraSIL Polymer-Housed VariSTAR Normal-Duty, Heavy-Duty and Riser Pole Distribution-Class Surge Arresters Certified Test Report
CP9232 Deadfront Arrester Cross Reference
CP9314 Deadfront Arresters Certified Test Report
CP9817 VariSTAR Type AGZ2 Surge Arrester, 10,000 A, Line Discharge Class 2 IEC 60099-4
CP9818 VariSTAR Type AZG3 Surge Arrester, 10,000 A, Line Discharge Class 3 IEC 60099-4
CP9819 VariSTAR Type AZG4 Surge Arrester, 20,000 A, Line Discharge Class 4 IEC 60099-4
CP0408 10 kA Class 2 Certified Test Report
CP0409 10 kA Class 3 Certified Test Report IEC 60099-4 2004
CP0605 CLU Arrester Certified Test Report
CP0606 UHS 10 kA Arrester Certified Test Report IEC 60099-4 2004
CP0804 UltraSIL Polymer-Housed Evolution Surge Arrester Certified Test Report
CP1012 UltraSIL Polymer-Housed Evolution Surge Arrester Design Test
CP1121 UltraSIL Polymer-Housed VariSTAR Type UI Intermediate-Class Surge Arresters Certified Test Report
CP1122 UltraSIL Polymer-Housed VariSTAR Type US, UH, and UX Station-Class Surge Arresters Certified Test Report
CP1219 10 kA Class 3 Certified Test Report IEC 60099-4 2009
CP1302 20 kA Class 4 Certified Test Report IEC 60099-4 2009
CP1313 Certified Test Report: UltraSIL™ Polymer-Housed VariSTAR™ Type UXL Strength Options B & C Station-Class Surge Arresters
Document Number White Papers
IEEE013 Overvoltage Protectors - A Novel Concept for Dealing with Overbuilt Distribution Circuits
IEEE-12 Watts Loss of Polymer Housed Surge Arrestes in a Simulated Florida Coastal Climate
Document Number Service Literature
S230-60-1 Type NR Oil Switch Installation Instructions
S230-60-8 Type NR Oil Switch Maintenance Instructions
S260-20-18 Type VR, VCR, VLR, VRV Switches & Type GV, GW Sectionalizers Crank Lever Replacement Kit Instructions
S260-15-2
(Discontinued)
Type VCS-1S Solenoid-Operated Capacitor Switch Operation & Installation Instructions
S260-15-3
(Discontinued)
VCS-1SX Solenoid-Operated Capacitor Switch Installation and Operation Instructions
S260-15-4
(Discontinued)
 VCS-1M Vacuum Capacitor Switch Installation and Operation Instructions
S260-75-1  Type S Automatic Load-Transfer Control Installation, Operation, and Maintenance Instructions
S260-80-2 iMC Switch Control Installation and Operation Instructions (Automated M-Force Switch is a Discontinued Product)
S260-80-1 Automated M-Force Switch Installation and Operation Instructions (Discontinued Product)
S260-15-1
(Discontinued)
Installation of Type VCS Switch
S260-60-1 Types DAS15, DAS27, and DAS38 Three-Phase; Vacuum-Break Distribution Automation Switch Installation and Operation  Instructions 
S260-60-3 Types DAS15, DAS27, and DAS38 Three-Phase Vacuum-Break Distribution Automation Switch and iDC Control Installation and Operation Instructions
S260-16-1 Installation of Type SyncCap Power Quality Switch
S260-62-1 Installation of Type VCS-3 Switch
S260-20-1
(See S230-60-1)
Installation of Types NR & NRV Oil Switches
S260-60-1S Installation of Type DAS (Spanish)
S260-20-1S Tipos NR y NRV
Instrucciones de instalación y funcionamiento
S260-20-8S
(See S230-60-8 for Replacement Parts)
Tipos NR, NRV
Instrucciones de mantenimiento
S260-20-10S Tipo TSC; trifásico;
Instrucciones de instalación
S260-50-1 Installation of Type F Switch
S260-20-8
(See S230-60-8 for Replacement Parts)
Maintenance of Types NR (S/N 30990 & After) & NRV (S/N 10500 & After)
S260-20-10 Installation of Type TSC Oil Switches
S260-50-2 Maintenance of Type F Switch
S260-20-6 Installation of Types VR, VLR, VCR Oil Switches
S260-20-6S Tipos VR, VLR, VCR, VRV
Instrucciones de instalación
S260-20-5
(See S230-60-8 for Replacement Parts)
Maintenance of Types NR & NRV Oil Switches
S260-20-9 Maintenance of Types VR, VCR, VLR Oil Switches
S260-20-9S Tipos VR, VCR y VLR
Instrucciones de mantenimiento
S260-01 through S280-01 Distribution Switchgear Parts Guide
Document Number Reference Literature
CP115 VCS-1M Test Report
R230-60-1 Type NR Oil Switch Service Part Number Cross Reference
R230-60-2 Type NR Oil Switch Spare Parts List
Document Number Service Literature
S201-10-1 Mineral Oil-Filled, Single-Phase Overhead Distribution Transformer Instructions
S201-20-1 Mineral Oil-Filled Installation & Maintennce-Single Phase Padmount Distribution Transformer Instructions
Document Number Reference Literature
R327-40-1 Recommended Type D Link Primary Fusing for Distribution Transformers
R327-40-2 Recommended Types X and KS Link Primary Fusing for Distribution Transformers
G201-10-1 Single-Phase Overhead-type Distribution Transformer Specification
G201-20-1 Single-Phase Pad-Mounted Distribution Transformer Specification
R201-90-2 Voltages & Connections for Distribution Transformers
90051 Low Voltage-Side Current Surge Phenomenon Single-Phase Distribution Transformer Systems
Document Number White Papers
W100-12014 DOE Energy Standards for Distribution Transformers
Document Number Service Literature
S210-12-1 Three-Phase Compartmental Padmounted Transformer Installation and Maintenance Instructions
S210-15-10 Substation Transformers Installation, Operation, Maintenance Instructions & Parts Replacement
Document Number Reference Literature
G210-12-2 Envirotran HDC Transformers 45-10,000 kVA Transformer Specification
G210-15-4 Envirotran HDC Transformer 112.5-10,000 kVA Specification
G210-15-1 Three-Phase Unit Substation Distribution Transformer Specification
G210-15-2 Three-Phase Indoor Unit Substation Transformer Specification
G210-15-3 Triplex Indoor Power Centers 750 - 2500 kVA Specification
G210-16-1 Three-Phase Open Substation Distribution Transformers Specification
G210-12-1 Three-Phase Pad-mounted Distribution Transformers Specification
G210-80-1 PEAK Three-Phase Pad-mounted Compartmental Type Functional Specification
G210-90-1 PEAK Three-Phase Substation Transformers Functional Specification
R210-80-4 Bolt-on vs. Weld-on Radiators Reference Document
R210-80-5 Isolated vs. Solidly Grounded Core Reference Document
R210-80-6 Rectangular vs. Round Coils Reference Document
R210-90-8 Design Options for Substation Transformer Protection and Isolation
R210-90-5 Harmonic Load Reference Document
R210-90-6 Power Factor Reference Document
R210-80-1 Bay-O-Net with ELSP vs. Drywell Canister Fusing
R210-80-2 Bolt-on vs. Weld-on covers
R210-80-3  Copper Vs. Aluminum Conductor
R210-90-1 When To Use A Substation Transformer
R210-90-2 VFI Transformer vs. Switchgear
R210-90-3 When To Use A Three-Phase Padmounted Transformer
R210-90-4 Overvoltage Protection for Padmounted Transformers
R240-000-1 Pad-Mounted Transformer Fusing Philisophies
Document Number White Papers
IEEE-011 Distributed Pad-mounted Substations
W100-12014 DOE Energy Standards for Distribution Transformers
W210-12063 Three-Phase and Substation Class Transformer Seismic Qualification
WP100-14061 Pressure Optimization of Medium-Voltage Liquid-Filled Transformers in Photovoltaic Solar Applications
Document Number Service Literature
S285-10-1 VFI Oil-Insulated Installation Instructions
S285-10-2 Type VFI SF6-Insulated, Vacuum Fault Interrupter; Installation, Operation and Maintenance Instructions
S285-15-1 Type ShrubLine VFI,Vacuum Fault
Interrupter,Installation,
Operation and Maintainance
Instructions
S285-10-4 Visible Break Switch Accessory Operation Instructions
S285-50-1 Type RVAC Vacuum Switchgear
S285-10-7 VFI Tester Operating Instructions
S285-70-1 Types PWH and PWVH; Three-Phase; Hydraulically Contolled Installation Instructions
S285-75-1 Kyle Tri-Phase, TPG, TPG with SCADA Electronic Control Installation & Operation Instructions
S285-20-1 Type MOST Switchgear
S285-60-3  Type PST-6 Automatic Source Transfer Switchgear
S285-50-2 Type RVAC, SF6-Insulated, Vacuum Break Switch; Installation, Operation and Maintenance Instructions
S285-60-1 Type PST-9 Automatic Source Transfer Switchgear Installation, Operation & Maintenance Instructions
S285-10-5 Type VFI Fault Interrupter with Tri-Phase Control Single-Phase Trip to Three-Phase Trip Conversion Kit KPA111 Installation Instructions
S285-10-3 SF6 Gas Top-Off Kit, KPA-1043-1 or KPA-1043-2 Operation Instruction
S285-75-3  Type VFI Tri-Phase Ground Control Retrofit Instructions & Internal CT Polarity Test Procedures
S285-71-1  Installation of Types PWE & PWVE Reclosers
S285-80-1  DC Motor Operator Control Installation & Operating Instructions
S285-90-2
(Discontinued)
Edison Modular Switchgear Connection Adapter and Bushing Field Replacement Instructions
S285-35-1
(Discontinued)
EMS Digital Control Installation, Programming and Operation Instructions
S285-90-1
(Discontinued)
Edison Modular Switchgear (EMS) Installation, Operation, and Maintenance Instructions
Document Number Reference Literature
R285-91-4 Three-Phase Digital "EMS" Control Time Current Curve
R285-91-3 Tri-Phase Control Time Current Curve
R285-10-1 Guide for Atmospheric Retrofilling of 38 kV (or lower) Fluid-filled Switchgear
Document Number Service Literature
S225-10-4C VR-32 & CL-4C Control Operation & Maintenance Instructions
S225-10-5 VR-32 & CL-2A Control Operation & Maintenance Instructions
S225-10-10 VR-32 & CL-5 Series Control Operation & Maintenance Instructions
S225-10-10 PSVR Pad-mounted Voltage Regulator Supplemental Installation, Operation, and Maintenance Instructions (used with S225-10-10)
S225-10-10P VR-32 & CL-5 Series Control Operation & Maintenance Instructions (Portuguese)
S225-10-18 Forced-Air Cooling Accessory, Operation and Maintenance Instructions/Parts Information
S225-10-30 VR-32 Voltage Regulator with Quik-Drive Tap-Changer Installation, Operation, and Maintenance Instructions
S225-10-30P Regulador de Tensao VR-32 com comutador Quik-Drive Instrucoes de instalacao, operacao e manutencao
S225-10-30S Instrucciones de instalación, funcionamiento y mantenimiento del regulador de voltaje VR-32 con cambiador de tomas Quik-Drive
S225-11-1 CL-6 Series Control Installation, Operation and Maintenance Instructions
S225-11-1F CL-6 Series Control Installation, Operation, and Maintenance Instructions (French)
S225-11-2
(Discontinued)
CL-6 Series Microprocessor-Based Regulator Control:Cooper Control Interface 4.01 Users Guide
S225-11-6 Tap-Changer Diagnostics
S225-12-1 QD3 Quik-Drive Voltage Regulator Tap Changer Manual (8M download)
S225-12-1F Manuel du changeur de prise pour regulateur de tension Quik-Drive QD3 (Canadian French)
S225-12-2 QD5 Quik-Drive Voltage Regulator Tap-Changer Manual
S225-15-1 32-Step Simplified Regulator Installation, Operating, and Maintenance Instructions
S225-20-1 4-Step Auto-Booster Line Regulator (Discontinued Product)
S225-20-2 Auto-Booster Regulator Control Description and Operational Instructions (Discontinued Product)
S225-30-1 Data Reader Operating Instructions
S225-40-4 Fiber-Optic/RS-232 Communications Module Installation and Operation Instructions
S225-40-7 RS-485 Digital Communications Accessory Board Installation and Operation Instructions
S225-40-8 Ethernet Communications Module Installation and Operation Instructions
S225-40-9 Leader/Follower Scheme Installation and Operation Guide
S225-50-2 Spring Drive Holding Switch Installation Instructions
S225-50-6 Retrofit 12-Conductor Cable Installation Instructions
S225-50-6F Instructions de remise a jour du cable a 12 conducteurs
S225-50-13 Quik-Drive T875 Tap Changer Main Stationary Contact Replacement Instructions
S225-50-14 McGraw-Edison Voltage Regulator Elevating Structure Assembly Instructions
S225-50-16 QD8 Tap Changer Motor Replacement Procedure Kit 57A63675100A
S225-50-19 T875 Quik-Drive Tap-Changer Brank Assembly Replacement Instructions
S225-50-27 CL-6A Control Retrofit Connector Kit Instructions
S225-50-28 Relay Retrofit Kit Instructions
S225-50-29 CL5 to CRA-DDR Connecter Kit 57A64317100D
S225-50-30 Conversion Kit for Pre-CL-6A Control Panels to Dead Front Back Panel
S225-50-31 Polymer Position Indicator Main Cover Replacement Kit 5742305B01
S225-50-32 Polymer Position Indicator Replacement Solenoid Kit 5742301B01
S225-50-35 QD3/T350 Motor Replacement Kit Number 57A63675100B
S225-50-37 QD3/T350 Motor Resistor Replacement Kit Number 572291844A01
S225-50-38 QD8 Movable Contact Board Replacement Procedure Kit 5742895B01
S225-50-40 QD3/T350 PI Drive Cam Replacement Kit Number 572240783B21
S225-50-41 QD3/T350 Main Stationary Contact Assembly Kit
S225-50-42 QD3/T350 Main Movable Contact Assembly Kit 5741325B04
S225-50-43 QD3/T350 Reversing Stationary Contact Assembly Instructions Kit 5791822A02
S225-50-44 QD3/T350 Reversing Movable Contact and Neutral Stationary Contact Assembly Kit, 5741325B03
S225-50-45 QD3/T350 TC-LTC P.I. Drive Face Gear Kit 5740787B11
S225-50-47 QD5 Reversing Movable Contact Assembly Kit Number 5740785B72ER
S225-50-48 QD5 Reversing Neutral Stationary Contact Assembly Kit 5791646A26 Installation Instructions
S225-50-49 QD5 Main Stationary Contact Assembly Kit Number 5791646A24
S225-50-50 QD5 VL Reversing Stationary Contact Assembly Kit Number 5791646A25
S225-50-51 QD5 VR Reversing Stationary Contact Assembly Kit Number 5791646A27
S225-50-52 QD5 Tap Changer Motor Replacement Procedure Kit Number 57A63675100A
S225-50-53 QD5 Main Movable Contact Replacement Kit Number 5740785B33
S225-50-54 CL-6B Control Panel Retrofit Installation Instructions
S225-50-55 CT Protector Retrofit Kit
S225-50-56 Auxiliary Quick-Disconnect Sealing Gasket Installation Instructions, Kit Number 57A64329500A
S225-60-2 Ratio Test Procedure Instructions
S225-60-3
Potential Transformer Ratio Test
S225-60-7 Procedure to Free a Stalled Tap-Changer
S225-60-8 Tapping to Neutral and Verifying Neutral Tap Position if Front Panel is Completely Inoperable
S225-60-10 External Application of a Motor Start Capacitor on a Single-Phase Voltage Regulator
S225-60-12 Testing a Motor Capacitor on a Voltage Regulator Procedure Instructions
S225-70-1 CL-7 Regulator Control Installation, Operation, and Maintenance Instructions
S225-70-4 CL-7 Voltage Regulator Control Replacement Assembly (CRA) Installation Instructions and Service Information
S225-70-5 CL-7 Control Panel Retrofit Installation Instructions
S225-70-6 CL-7 Voltage Regulator Control Communications Module Installation Instructions
S225-70-7 Back Panel Upgrade 10- to 18-position Terminal Strip Installation Instructions for CL-7 Regulator Control
S225-70-13 Input/Output (I/O) Module Installation Instructions
Document Number Reference Literature
R225-01-1 Leader/Follower Scheme for Voltage Regulator Controls
R225-10-1 Regulator Compensation Settings
R225-60-13 Communication Cable Retrofit
R225-70-27 Interoperability for Communications Protocol IEC 60870-5-104
R225-70-28 Interoperability for Communications Protocol IEC 60870-5-101
R225-70-29 Communications Point Data Base for Communications Protocol 2179
R225-70-30 Communications Point Data Base for MODBUS Protocol
R225-70-31 Communications Point Data Base for Serial and Ethernet Communications Protocol DNP3
R225-70-32 Communications Point Data Base for Communications Protocol IEC 60870-5
R225-70-33 Interoperability for Communications Protocol IEC 61850
R225-70-34 Communications Point Data Base for Communications Protocol IEC 61850
R225-70-35 Communications Point Availability-Available Data Points for CL-7 Communications
R225-80-3 Certificate of Performance of Protective Coatings for Voltage Regulators
R225-80-4 Description of Protective Coatings for Voltage Regulators
R225-80-4P Descricao para camada anti-corrosiva de Reguladores de Tensao (Portuguese)
R225-80-9 Routine Production Testing of Voltage Regulators
R225-90-7 Voltage Regulator and Recloser Data Reader Program Reference Manual
R225-90-11 CL-6A Regulator Control DNP3 Device Profile Document
R225-90-12 CL-6 Series IEC60870-5-101 Protocol Device Profile Data Dictionary
R225-90-21 Voltage Regulator vs. Load Tap Changers
77006 How Step Voltage Regulators Operate
89024 CL-4C Function Codes
Document Number White Papers
W225-10022 Regulator Efficiency: Considerations for Design and Loss Evaluations