UL high SCCR SPDs

bue-ele-ul-spd-3-pole-220.jpg

Surge Protection Made Simple™ for UL 508A applications requiring high SCCR

  • Comprehensive High SCCR surge protection solutions for North American
    UL 508A applications
  • UL 1449 4th Edition Recognized and CSA Approved SPD devices provide optimum surge protection for the United States and Canadian panel markets
  • Modular DIN-rail design with color coding and rejection feature makes it easy to identify, install and maintain
  • easyID™ local visual indication and optional remote contact signaling make status monitoring simple
  • Vibration and shock resistant according to EN 60068-2 standards to withstand harsh environments
  • IP20 finger-safe design improves electrical safety

The need for surge protection


Today’s world is full of electronic products and devices that are susceptible to damage from overvoltage surges.

Whether the cause is static discharge or lightning, overvoltage surges can quickly destroy consumer electronics or sophisticated electronic packages used in industrial and commercial applications.

Bussmann surge protection products help provide power quality that’s free from damaging surges and overvoltage conditions.

Safe and Simple

  • IP20 finger-safe construction and suppressor rejection feature make it easy to know the suppressor system is installed and properly operating to protect your equipment investment
  • Simply specify the system voltage and whether the remote contact signaling is desired
  • Five year limited warranty

Product profile no. 3190

Data sheets (See Spec Sheets and Downloads tab below)

Application guide no. 3193

Installation sheets (See Spec Sheets and Downloads tab below)

CAD drawings (See Spec Sheets and Downloads tab below)

Surge protective device master spec no. 10204

Warranty statement no. 3A1502

Competitor cross reference

Bussmann series SPD selector

Find the surge protective device you need based upon your overvoltage protection needs - covers power and data signal SPDs.

Catalog symbol
Technology Poles/wires Nominal voltage System type Remote  contact signalin
BSP M = MOV

1 = 2 wire

2 = 2 wire / 3 Wire

3 = 3 wire

4 = 4 wire

120=120V

208=208V

240=240V

347=347V

480=480V

600=600V

S2G = single-phase 2 wire w/ Gnd

S3G = single-phase (split) 2 wire / 3 wire w/ Gnd

DLG = Delta w/ Gnd

HLG = Highleg Delta w/ Gnd

WYG = Wye w/ Gnd

WYNG = Wye w/ neutral and Gnd

Blank = no remote

R = with remote

UL-SPD catalog number Description Replacement module (Qty) Poles AC voltage SCCR kA cULus Recognized
CSA
BSPM1120S2G 127V single-phase (Mexico)120V single-phase (USA) BPM275UL (1x) 1 120 200 Y
BSPM1120S2GR

127V single-phase (Mexico) with remote 

120V single-phase (USA) with remote

BPM275UL (1x) 1 120 200 Y
BSPM1240S2G

240V single-phase (USA)

254V single-phase (Mexico)

277V single-phase (USA)

BPM385UL (1x) 1 240 200 Y
BSPM1240S2GR

240V single-phase (USA) with remote

254V single-phase (Mexico) with remote

277V single-phase (USA) with remote

BPM385UL (1x) 1 240 200 Y
BSPM1347S2G 347 V single-phase  (USA) BPM600UL (1x) 1 347 125 Y
BSPM1347S2GR 347 V single-phase  (USA) with remote BPM600UL (1x) 1 347 125 Y
BSPM2240S3G

127/254V split phase - 1Ø 3W+Gnd (Mexico)

240V  corner Gnd Delta, 1Ø 2W+Gnd (USA)

BPM275UL (2x) 2 240 200 Y
BSPM2240S3GR

127/254V split phase - 1Ø 3W+Gnd (Mexico) with remote

240V corner Gnd Delta, 1Ø 2W+Gnd (USA) with remote

BPM275UL (2x) 2 240 200 Y
BSPM2480S3G

240/480 split phase - 1Ø 3W+Gnd (USA)

480V corner Gnd Delta, 1Ø 2W + Gnd (USA)

BPM385UL (2x) 2 480 200 Y
BSPM2480S3GR

240/480 split phase - 1Ø 3W+Gnd (USA) with remote

480V corner Gnd Delta, 1Ø 2W + Gnd (USA) with remote

BPM385UL (2x) 2 480 200 Y
BSPM3240DLG 240V Delta - 3Ø 3W+Gnd (USA) BPM275UL (3x) 3 240 200 Y
BSPM3240DLGR 240V Delta - 3Ø 3W+Gnd (USA) with remote BPM275UL (3x) 3 240 200 Y
BSPM3480DLG 480V Delta - 3Ø 3W+Gnd & HRG Wye (USA) BPM600UL (3x) 3 480 125 Y
BSPM3480DLGR 480V Delta - 3Ø 3W+Gnd & HRG Wye (USA) with remote BPM600UL (3x) 3 480 125 Y
BSPM3208WYG 120/208 Wye 3Ø 3W+Gnd BPM275UL (3x) 3 208 200 Y
BSPM3208WYGR 120/208 Wye 3Ø 3W+Gnd with remote BPM275UL (3x) 3 208 200 Y
BSPM3480WYG 277/480 Wye 3Ø 3W+Gnd BPM385UL (3x) 3 480 200 Y
BSPM3480WYGR 277/480 Wye 3Ø 3W+Gnd with remote BPM385UL (3x) 3 480 200 Y
BSPM3600WYG 347/600 Wye 3Ø 3W+Gnd BPM600UL (3x) 3 600 125 Y
BSPM3600WYGR 347/600 Wye 3Ø 3W+Gnd with remote BPM600UL (3x) 3 600 125 Y
BSPM4240HLG 120/240 Highleg Delta - B High (USA) BPM275UL (4x) 4 240 200 Y
BSPM4240HLGR 120/240 Highleg Delta - B High (USA) with remote BPM275UL (4x) 4 240 200 Y
BSPM4480HLG 240/480 3-phase Highleg  3Ø 3W+Gnd

BPM385UL (3x)

BPM600UL (1x)

4 480 125 Y
BSPM4480HLGR 240/480 3-phase Highleg  3Ø 3W+Gnd with remote

BPM385UL (3x)

BPM600UL (1x)

4 480 125 Y
BSPM4208WYNG

120/208 Wye - 3Ø 4W+Gnd (USA)

127/220 Wye - 3Ø 4W+Gnd (Mexico)

BPM275UL (4x) 4 208 200 Y
BSPM4208WYNGR

120/208 Wye - 3Ø 4W+Gnd (USA) with remote

127/220 Wye - 3Ø 4W+Gnd (Mexico) with remote

BPM275UL (4x) 4 208 200 Y
BSPM4480WYNG 277/480 Wye - 3Ø 4W+Gnd (USA)

BPM385UL (3x)

BPM275UL (1x)

4 480 200 Y
BSPM4480WYNGR 277/480 Wye - 3Ø 4W+Gnd (USA) with remote

BPM385UL (3x)

BPM275UL (1x)

4 480 200 Y
BSPM4600WYNG 347/600 Wye - 3Ø 4W+Gnd (Canada)

BPM600UL (3x)

BPM275UL (1x)

4 600 125 Y
BSPM4600WYNGR 347/600 Wye - 3Ø 4W+Gnd (Canada) with remote

BPM600UL (3x)

BPM275UL (1x)

4 600 125 Y