The Only, True UL 1449 3rd Edition Recognized SPD to Protect Your PV Investment from Damaging Surges and Overvoltages

New Lightning Arrester
The Cooper Bussmann combined lightning current and surge arrester (SPD Class I according to IEC 61643-1) for use in photovoltaic power supply systems.

New Two Module Surge Protector
This Cooper Bussmann modular Surge Protective Device (SPD) (with two-step DC switching device) features easy ID™ visual indication and optional remote contact signaling (floating changeover contact) for use in photovoltaic systems.
This complete surge protective device is suitable for all PV systems in accordance with UL 1449 3rd Edition and IEC 60364-7-712. Includes a five year limited warranty.
This prewired solution consist of a base and locking modules that feature a combined disconnection and short-circuiting (shunting) device with safe electrical isolation to prevent fire damage due to DC arcs. An integrated DC fuse allows safe module replacement without arc formation.
The Need for Surge Protection
The unique nature of PV installations make them vulnerable to overvoltages and surges from lightning strikes and static discharges.
These surges need to be intercepted before they take down the entire system by damaging the PV arrays, charge controller/inverter and combiner boxes.
In any PV system, it is vital that surge suppressor elements that are subject to wear, are easily monitored for performance.
The Cooper Bussmann PV Surge Suppression systems provide standard easyID™ visual indication and remote contact signaling to keep system maintainers apprised of the protection level being delivered.
Safe and Simple
Data Sheets (See Spec Sheets and Downloads tab below)
Installation Sheets (See Spec Sheets and Downloads tab below)
| Part Numbers and Voltage Ratings | ||||
|---|---|---|---|---|
| One Module Lightning Arrester | ||||
| BSPS31000PV | 1000V | |||
| Two Module Surge Arrester | ||||
| Maximum continuous operating voltage for PV applications [UCPV] | 600Vdc | |||
| Catalog Numbers (Base + Modules): | Without Remote Signaling | BSPH2600PV | ||
| With Remote Signaling | BSPH2600PVR | |||
| Three Module Surge Arrester | ||||
| Maximum continuous operating voltage for PV applications [UCPV] | 600Vdc | 1000Vdc | 1200Vdc | |
| Catalog Numbers (Base + Modules): | Without Remote Signaling | BSPH3600YPV | BSPH31000YPV | BSPH31200YPV |
| With Remote Signaling | BSPH3600YPVR | BSPH31000YPVR | BSPH31200YPVR | |
| Replacement Modules: | Outer (2) | BPH300YPV | BPH500YPV | BPH600YPV |
| Center (1) | BPM300YPV | BPM500YPV | BPM600YPV | |