Class CC, Midget & 10x38 CCP_

Compact Circuit Protector (CCP_) Class CC, Midget & 10x38

The revolutionary Bussmann CCP is 2/3 the footprint of traditional fusible switch and can provide up to a high 200kA AC SCCR that can help increase assembly SCCR.

CCP product profile no. 3139

CCP data sheet no. 1157

Application note no. 7038

Full line catalog no. 1007, Section 11, Disconnect Switches

3-D model drawings

Frequently Asked Questions (FAQs)  

Press release

Agency cards

 

Contact Information

Ordering: (636) 527-3877

Technical Support: (636) 527-1270

E-mail

Catalog Number CCP-(poles)-30CC Class CC Fuses, CCP-(poles)-30M Midget & 10x38 Fuses, CCP-1-DCC DC Rated Class CC Fuses, CCP-1-DCM DC Rated Midget & 10x38 Fuses
Dimensions/ Volts/ Amps See Data Sheet # 1157
Agency Information • For Class CC fuse version UL 98 Listed, File E302370, Guide WHTYcULus to CSA Standard 22.2 No. 4-04,
File 302370, Guide WHTY7 CE Compliant
• For UL Midget and 10X38 IEC fuse version UL 508 Listed, File E161278, Guide 8R29 cULus Certified 22.2
No. 14-05 IEC 60947-3 AC23A IEC 60947-3 DC23A CE Compliant
Ratings • Box Lug Connection: 18-6AWG single or dual rated, solid or stranded – 75ºC or higher - Cu only,
4AWG single – 75ºC or higher - Cu only
• Spade Terminal Connection: Max 30A suitable for use with #8-32UNC screw
• Box Lug and Spade Terminal suitable for line, load or accessory connection
• Torque: 18-10AWG 20 lb-in 8-4AWG 35 lb-in
• Lock-out/tag-out: 4mm shank lock or standard pin-out devices
• 35mm DIN Rail Mount
• Local indication minimum operating voltage: 90Vac for AC version, 12Vdc for DC version
Environmental Data • RoHS Compliant: Yes
• Storage and Operating Temperature: -20ºC to 75ºC**
• CE Compliant: Yes **For fuse performance under or above 25ºC, consult fuse performance derating
charts in the Cooper Bussmann publication titled Selecting Protective Devices (SPD) reorder #3002.
Operating Temperature Range -20°C to +75°C (for operation over or under 25°C, consult fuse derating tables)

Features

  • Extremely compact design at 17.5mm wide per pole
  • High Short-Circuit Current Ratings up to 200kA
  • Disconnect Rated to provide means for load isolation
  • Full Voltage Rated 600Vac or 80Vdc
  • UL 98 disconnect rated for protection of branch circuits with Low-Peak Class CC fuses
  • Suitable for Global Installations, the units Complies with UL, CSA, and IEC standards accepting UL Class CC, Midget or IEC aM and gG fuses
  • Horsepower rated for protecting motor circuits with Class CC units
  • Open Fuse Indication Local fuse indication lights* are standard Optional wired remote open fuse indication can be utilized to signal a PLC and open a contactor to de-energize all phases, if required
  • IP20 finger-safe construction with 10AWG wire or larger
  • Built-in switch interlock capability prohibits removing the fuse under load
  • Padlockable handle for lock-out/tag-out procedures
  • Available in 1-, 2- and 3-pole versions

*Circuit must be closed for indication light to illuminate

Related Products and Accessories