CUBEFuse CCP2-CF

Now with rotary operators and multi-wire lug kits

The revolutionary Bussmann™ series Compact Circuit Protector (CCP) for Class CF Low-Peak™ CUBEFuse™ delivers the smallest footprint compared to any Class J disconnect solution — requiring up to 51% less space.

The CCP is a UL® 98 Listed fused, branch-circuit disconnect that packs up to a 200 kA short-circuit current rating (SCCR) at 600 V to help increase equipment SCCR. These high ratings and compact design make the CCP ideal for industrial control panels, machinery and HVAC applications.

CCP2 product profile no. 10809

CCP2 data sheet no. 10801

TCF CUBEFuse product profile no. 3083.  

FAQs no. 10825

CCP2 switch install instructions no. 3A3600

3- and 6-port multi-wire lug kit install instructions no. 3A3734

Selector and pistol handle install instructions no. 3A3695

CCP2B product profile no. 10270

CCP2B data sheet no. 1161

CCD2 non-fused disconnect data sheet no. 10004

Legacy CCP data sheet no. 1157

Legacy CCP-CF end of life notice and recommended replacements

Legacy CCPB-CF end of life notice and recommended replacements

Catalog no. Poles Description Volts SCCR Max Hp rating (Vac)  
          120 240 480 600
30 amp switches
CCP2-1-30CF 1 Switch only 347 Vac/125 Vdc 200 kA AC/100 kA DC 1.5 - - -
CCP2-2-30CF 2 600 Vac/125 Vdc - 3 - -
CCP2-3-30CF 3 600 Vac - 5 15 10
CCP2R-2-30CF 2 Right front rotary, clockwise operated switch 600 Vac/125 Vdc - 3 - -
CCP2R-3-30CF 3 600 Vac - 5 15 10
CCP2RL-2-30CF 2 Left front rotary, clockwise operated switch 600 Vac/125 Vdc - 3 - -
CCP2RL-3-30CF 3 600 Vac - 5 15 10
CCP2S-2-30CF 2 Right side rotary, clockwise operated switch 600 Vac/125 Vdc - 3 - -
CCP2S-3-30CF 3 600 Vac - 5 15 10
CCP2SL-2-30CF 2 Left side rotary, counterclockwise operated switch 600 Vac/125 Vdc - 3 - -
CCP2SL-3-30CF 3 600 Vac - 5 15 10
60 amp switches
CCP2-1-60CF 1 Switch only 347 Vac/125 Vdc* 200 kA AC/100 kA DC 3 - - -
CCP2-2-60CF 2 600 Vac/125 Vdc* - 7.5 - -
CCP2-3-60CF 3 600 Vac - 7.5 20 10
CCP2R-2-60CF 2 Right front rotary, clockwise operated switch 600 Vac/125 Vdc* - 7.5 - -
CCP2R-3-60CF 3 600 Vac - 7.5 20 10
CCP2RL-2-60CF 2 Left front rotary, clockwise operated switch 600 Vac/125 Vdc* - 7.5 - -
CCP2RL-3-60CF 3 600 Vac - 7.5 20 10
CCP2S-2-60CF 2 Right side rotary, clockwise operated switch 600 Vac/125 Vdc* - 7.5 - -
CCP2S-3-60CF 3 600 Vac - 7.5 20 10
CCP2SL-2-60CF 2 Left side rotary, counterclockwise operated switch 600 Vac/125 Vdc* - 7.5 - -
CCP2SL-3-60CF 3 600 Vac - 7.5 20 10
100 amp switches
CCP2-1-100CF 1 Switch only 347 Vac/125 Vdc** 200 kA AC/100 kA DC 5 - - -
CCP2-2-100CF 2 600 Vac/125 Vdc** - 10 - -
CCP2-3-100CF 3 600 Vac - 20 50 40
CCP2R-2-100CF 2 Right front rotary, clockwise operated switch 600 Vac/125 Vdc** - 10 - -
CCP2R-3-100CF 3 600 Vac - 20 50 40
CCP2RL-2-100CF 2 Left front rotary, clockwise operated switch 600 Vac/125 Vdc** - 10 - -
CCP2RL-3-100CF 3 600 Vac - 20 50 40
CCP2S-2-100CF 2 Right side rotary, clockwise operated switch 600 Vac/125 Vdc** - 10 - -
CCP2S-3-100CF 3 600 Vac - 20 50 40
CCP2SL-2-100CF 2 Left side rotary, counterclockwise operated switch 600 Vac/125 Vdc** - 10 - -
CCP2SL-3-100CF 3 600 Vac - 20 50 40
* 125 Vdc for installed fuse amp ratings up to 40 A. 24 Vdc for installed fuse amp ratings from 45 to 60 A.
** 125 Vdc for installed fuse amp ratings up to 80 A, 24 Vdc for installed fuse amp ratings from 90 to 100 A.